sglux-logo
bag-icon 1
Generic filters
Exact matches only
en
  • Shop
    • UV Photodiodes
    • UV TOCONs
      Photodiodes with integrated signal amplifier
    • UV Sensors
    • UV Radiometers
    • Customized solutions
    • UV Calibration
    • UV Index Measurement
    • Transducers for photodiodes
  • sglux ESG concept
  • Research
  • About Us
  • Contact Us
    • Distributors
    • Privacy Policy
    • Imprint
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Research
  • About Us
  • Contact Us
Home / Products / Transducers for photodiodes

Transducers for photodiodes

“Photodiode Amplifier Connect” has been added to your cart. View cart

    Photodiodes convert incoming electromagnetic radiation into electrical charge carriers. If photodiodes are short circuited an electrical current (photocurrent) proportional to the incident radiation intensity (number of photons per second) is induced. These photocurrents are generally small and cover the range from femtoampere (fA) to microampere (µA). Signal transducers transform this weak photocurrent to robust standard signals for reliable data transmission and simple data acquisition.

The voltage which is present on the open pins of a photodiode without a short circuit (photovoltage) can be easily measured with a voltmeter but is strongly non-linear correlated to the radiation intensity and thus not very useful for the measurement thereof.
The transducers developed by sglux employ transimpedance amplifiers which short the photodiodes and therefore provide a linear relationship between the incident radiation intensity and the output signal.
We offer analogue transducers with voltage output „VOLTCON (0 … +4V)“, „Multiboard (0 … ±4 V)“, „Digiboard (0 … ±3 V)“ and „Radikon (0 … +10 V)“ and current loop output „AMPCON (4 … 20 mA)“.
Furthermore we produce digital transducers which convert the photocurrent into digital representation transmitted to a computer via USB (Digiprobe, SGCD4). These transducers offer an increased dynamic range compared with the analogue transducers.
To control industrial UV applications our „SENSOR MONITOR 5.0“ supports multiple functions such as limit control, dosage control, lamp monitoring.

Showing all 10 results

Grid view List view
  • VOLTCON

    VOLTCON

    Transducer photocurrent-to-voltage 0 - 5 V, four different measurement ranges available: 500 pA, 50 nA, 5 µA and 500 µA, also available with enclosure, power supply and calibrationTransducer photocurrent-to-voltage 0 - 5 VSingle Price: 59€
    Product Description
    • transducer photocurrent-to-voltage 0 – 5 V
    • maximum photocurrent: 500 µA, 5 µA, 50 nA or 500 pA
    • new version (“advanced”) with improved features (see data sheet) now available. However, repeat orders should use the “legacy” version, as the adjustment options differ (legacy = 0% … -100% and advanced = +35% … -35%).
    • also available with enclosure, power supply and calibration
  • AMPCON

    AMPCON

    Transducer photocurrent-to-current 4 – 20 mA, three different measurement ranges available: 25 nA, 2.5 µA and 250 µATransducer (current amplifier) with output current 4 to 20 mASingle Price: 59€
    Product Description
    • transmitter (current amplifier) with output current 4 to 20 mA
    • to include photodiodes into an industrial 4 to 20 mA data bus
    • maximum photocurrent: 250 µA, 2.5 µA or 25 nA
  • Multiboard (TW-MF2CAB)

    Multiboard (TW-MF2CAB)

    Two-channel photocurrent-to-voltage transducer 0 – 4 V, jumper selectable measurement ranges from 400 nA to 40 µA. Best suited for experiments where the photocurrent to be measured is yet unknown. Universal dual channel photodiode transducerSingle Price: 99€
    Product Description
    • universal dual channel photodiode transducer
    • measuring range from 400 nA range up to 400 µA
    • versatile configuration possible
    • well suited for experimental setups and small series
  • Digiboard

    Digiboard

    Transducer for the conversion of a photocurrent to a voltage of 0 - 3 V or a photocurrent to a frequency. The programmable limit switch with hysteresis allows the Digiboard to be used as a simple controller unit. The measurement ranges from 300 nA to 30 µA can be configured by jumpers. A potentiometer allows trimming of the voltage output to a defined value. The frequency output offers a high dynamic range of 6 decades.Versatile dual channel current to voltage converting amplifierSingle Price: 149€
    Product Description
    • versatile dual channel current to voltage converting amplifier
    • one analog and one frequency output
  • SGCD4

    SGCD4

    The SGCD4 is a switchable gain photocurrent digitizer that converts small DC currents (e.g. generated by photodiodes) into digital values transmitted via USB to a computer for displaying and recording. Four different current measurement ranges are user selectable by software. The device is delivered with a PTB traceable current calibration.switchable gain photocurrent digitizer, converts small DC currents into digital values, different current measurement rangesSingle Price: 520€
    Product Description
    • switchable gain photocurrent digitizer, converting small DC currents (e.g. generated by photodiodes) into digital values transmitted via USB to a computer for displaying and recording
    • four switchable gain levels
    • no specific previous metrological knowledge needed
    • delivered with a PTB traceable current calibration
    • low noise cable available on request
  • Mounted photodiode

    Mounted photodiode

    Photodiode in housing with BNC connectionPhotodiode in housing with BNC connectionSingle Price: 130€
    Product Description
    • Photodiode in M12x1 housing with BNC connection
    • Suitable for all sglux UV photodiodes
    • A mounting plate for optical benches is optionally available.
    • An integrated shunt resistor is optionally available, resistance value according to customer specifications.
  • RADIKON-simple

    RADIKON-simple

    The Radikon-Simple bases on a VOLTCON or AMPCON and comes with a rugged shielded housing with BNC connector.External amplifier box to convert the photocurrentSingle Price: 155,00€
    Product Description
    • external amplifier box to convert the photocurrent of photodiodes or the sglux UV-Cure-HT sensor
    • signal output 0 – 5 V, 4 – 20 mA or USB
    • the gain is configured customer-specifically
    • the module is also available with calibration
    • robust, shielded housing with BNC input
  • SENSOR MONITOR 5.0

    SENSOR MONITOR 5.0

    Measuring and control module for monitoring and automation of irradiation processes. The device provides the display of irradiance and dose information for up to two UV sensors as well as three programmable relays for control of multi-stage irradiation processes.Measuring and control module for monitoring and automation of irradiation processesSingle Price: 490,00€
    Product Description
    • measuring and control module for monitoring and automation of irradiation processes
    • indication of radiation, dose and status information
    • three programmable relays for automation of single- and multi-level irradiation processes
    • optional with two measuring inputs and USB/RS232 output
  • Photodiode Amplifier Dual

    Photodiode Amplifier Dual

    The Photodiode Amplifier Dual is based on the Multiboard and comes with a rugged shielded housing, well suited for experimental setups.Two-Channel Photocurrent AmplifierSingle Price: 420€
    Product Description
    • two-channel photocurrent amplifier
    • conversion of photocurrent into a 0 … 5 V output signal
    • maximum photocurrent: 100 pA … 40 µA
    • suited for experimental setups in measurement laboratories
  • Photodiode Amplifier Connect

    Photodiode Amplifier Connect

    The Photodiode Amplifier Dual is based on the Digiboard and comes with a rugged shielded housing, well suited for experimental setups.Photocurrent amplifier with integrated relay outputSingle Price: 450€
    Product Description
    • photocurrent amplifier with integrated relay output
    • conversion of photocurrent into a 0 … 5 V output signal
    • maximum photocurrent: 100 pA … 40 µA
    • suited for experimental setups in measurement laboratories

We gladly advise you on this product

Romana Sonnenberg
Romana Sonnenberg
Dipl.-Ing.

+49 (0) 30 53015211
Tilman Weiss
Tilman Weiss
Dr.-Ing.

+49 (0) 30 53015211

Warenkorb

FAQ

This content is only available in English
What is the power input of a Multiboard?
The current consumption of a Multiboard is between 4 mA and 20 mA, depending on the amount and type of operating voltage (uni / bipolar) as well as the load at the output (multimeter = no load).
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Imprint Privacy policy LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies