Silicon (Si)
spectral sensitivity from 290 to 1010 nm, peak wavelength 626 nm,
for VIS measurements, sorted by irradiance.

Showing all 10 results
-
TOCON_SI1
VIS, approx. 1.8 pW/cm² ... 18 nW/cm², TO5 lens capProduct Description- Si based photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is 18 nW/cm²
- min. irradiance (resolution limit) is 1.8 pW/cm²
- for very low radiation measurement such as stray light detection
-
TOCON_SI2
VIS, approx. 18 pW/cm² ... 180 nW/cm², TO5 lens capProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with lens cap, suited for flame detection
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 180 nW/cm2
- min. irradiance (resolution limit) is 18 pW/cm2
-
TOCON_SI3
VIS, approx. 180 pW/cm² ... 1.8 µW/cm², TO5 + diffusorProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 1.8 µW/cm2
- min. irradiance (resolution limit) is 180 pW/cm2
-
TOCON_SI4
VIS, approx. 1.8 nW/cm² ... 18 µW/cm², TO5 + diffusorProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 18 µW/cm2
- min. irradiance (resolution limit) is 1.8 nW/cm2
-
TOCON_SI5
VIS, approx. 18 nW/cm² ... 180 µW/cm², TO5 + diffusorProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 180 µW/cm2
- min. irradiance (resolution limit) is 18 nW/cm2
-
TOCON_SI6
VIS, approx. 180 nW/cm² ... 1.8 mW/cm², TO5 + diffusorProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 1.8 mW/cm2
- min. irradiance (resolution limit) is 180 nW/cm2
-
TOCON_SI7
VIS, approx. 1.8 µW/cm² ...18 mW/cm², TO5 + diffusorProduct Description- Si based photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is 18 mW/cm²
- minimum radiation (resolution limit) is 1.8 µW/cm²
- ambient light measurement
-
TOCON_SI8
VIS, approx. 18 µW/cm² ... 180 mW/cm², TO5 + attenuatorProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 180 mW/cm2
- min. irradiance (resolution limit) is 18 µW/cm2
-
TOCON_SI9
VIS, approx. 180 µW/cm² ... 1.8 W/cm², TO5 + attenuatorProduct Description- Si photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is approx. 1.8 W/cm2
- min. irradiance (resolution limit) is 180 µW/cm2
- UV hardening control and other very high radiation sources
-
TOCON_SI10
VIS, approx. 1.8 mW/cm² ... 18 W/cm², TO5 + attenuatorProduct Description- Si based photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 626 nm (peak wavelength) is 18 W/cm²
- min. irradiance (resolution limit) is 1.8 mW/cm²
- sun light measurement