sglux-logo
bag-icon 1
Generic filters
Exact matches only
en
  • Shop
    • UV Photodiodes
    • UV TOCONs
      Photodiodes with integrated signal amplifier
    • UV Sensors
    • UV Radiometers
    • Customized solutions
    • UV Calibration
    • UV Index Measurement
    • Transducers for photodiodes
  • sglux ESG concept
  • Research
  • About Us
  • Contact Us
    • Distributors
    • Privacy Policy
    • Imprint
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Research
  • About Us
  • Contact Us
Home / Products / UV TOCONs / Page 2

UV TOCONs

“TOCON_ABC2” has been added to your cart. View cart
  • SiC based UV sensor with integrated amplifier and 0 – 5 V voltage output
  • Measures intensities from 1.8pW/cm² up to 18W/cm²
  • Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index
  • Also available for blue light (GaP chip) or visible light (Si chip) measurement.
  • Available in TO5 housings or as miniature sensor probes (stainless steel or plastic).
  • Special TOCONs for hydrogen flame sensing (TOCON_F) and for fire detection (TOCON_N) available.
  • Also available for operating temperatures up to 120°C (standard is 85°C).
  • Direct connection of a TOCON to modules such as Arduino or Raspberry Pi possible.
  • Please learn more about the sglux TOCONs here: TOCON selection guide and here: TOCON User Guide.

All TOCONs are always on stock, no minimum order quantity. They can be ordered via our web shop or with an email addressed to welcome@sglux.de. Alternatively, we are happy to issue a quotastion or you may click on our shop’s QUOTATION function, instead of CHECKOUT.

Showing 31–48 of 48 results

Grid view List view
  • TOCON_A9

    TOCON_A9

    UVA, approx. 100 µW/cm² ... 1.0 W/cm², TO5 + attenuatorSingle Price: 138,00€
    Product Description
    • UVA photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with attenuator
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 331 nm (peak wavelength) is approx. 1.0 W/cm2
    • min. irradiance (resolution limit) is 100 µW/cm2
  • TOCON_F

    TOCON_F

    UVA+UVB+UVC, approx. 0.05 nW/mm² ... 10 nW/mm², TO5 lens cap, hydrogen flame detection Single Price: 138,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated logarithmic amplifier, linear measuring range up to 2,100 mV through the use of a SiC junction diode
    • TO5 hermetically sealed metal housing with lens cap
    • designed for hydrogen flame detection according to EN298
    • 0…3V – signal output
    • typical irradiation intensity 0.05 nW/mm²…10 nW/mm²
    • replacement for UV sensor SFH530 and UVTRON tubes
    • for evaluation purposes several housing options are available on request
    • We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
  • TOCON_ABC1

    TOCON_ABC1

    UVA+UVB+UVC, approx. 1.8 pW/cm² ... 18 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesSingle Price: 138,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • detection of hydrocarbon fuel flames and hydrogen flames according to EN298
    • TO5 hermetically sealed metal housing with lens cap
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 18 nW/cm2
    • min. irradiance (resolution limit) is 1.8 pW/cm2
    • replaces obsolete Perkin Elmer UV10.T2E.10L and UV10.SF
    • replacement for discharge flame sensors
    • We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
  • TOCON_ABC2

    TOCON_ABC2

    UVA+UVB+UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesSingle Price: 138,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • detection of hydrocarbon fuel flames and hydrogen flames according to EN298
    • TO5 hermetically sealed metal housing with lens cap
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 180 nW/cm2
    • min. irradiance (resolution limit) is 18 pW/cm2
    • replacement for discharge flame sensors
    • We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
  • TOCON_C1

    TOCON_C1

    UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5 housing without diffusorSingle Price: 158,00€
    Product Description
    • UVC photodetector with integrated amplifier
    • large 1 mm² SiC detector chip to maximize sensitivity
    • TO5 hermetically sealed metal housing
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 254 nm is 180 nW/cm2
    • min. irradiance (resolution limit) is 18 pW/cm2
  • TOCON_NC1F

    TOCON_NC1F

    UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5, fire detection, fast response time, TO5 housing with diffusorSingle Price: 158,00€
    Product Description
    • UVC photodetector with integrated amplifier
    • with fast response time for fire detection
    • large 1 mm² SiC detector chip to maximize sensitivity
    • with diffusor for broadening of the field of view
    • TO5 hermetically sealed metal housing
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 254 nm is 180 nW/cm2
    • min. irradiance (resolution limit) is 18 pW/cm2
    • This TOCON needs a positive and a negative power supply. For product evaluation the TOCON_N_steel housing with integrated bias generator is available.
    • replacement for discharge flame sensors
  • TOCON_SI1

    TOCON_SI1

    VIS, approx. 80 µlux … 80 mlux, TO5 lens capSingle Price: 138,00€
    Product Description
    • Si based photodetector with integrated amplifier for lux measurements
    • TO5 hermetically sealed metal housing with lens cap
    • 0 … 5 V signal output
    • max. illuminance (saturation limit) at 560 nm (peak wavelength) is 80 mlux
    • min. illuminance (resolution limit) is approx. 80 µlux
    • for very low illuminance measurement such as stray light detection
  • TOCON_ABC3

    TOCON_ABC3

    UVA+UVB+UVC, approx. 180 pW/cm² ... 1.80 µW/cm², TO5 + diffusorSingle Price: 123,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with diffusor
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 µW/cm2
    • min. irradiance (resolution limit) is 180 pW/cm2
  • TOCON_ABC4

    TOCON_ABC4

    UVA+UVB+UVC, approx. 1.8 nW/cm² ... 18 µW/cm², TO5 + diffusorSingle Price: 123,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with diffusor
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 µW/cm2
    • min. irradiance (resolution limit) is 1.8 nW/cm2
  • TOCON_ABC5

    TOCON_ABC5

    UVA+UVB+UVC, approx. 18 nW/cm² ... 180 µW/cm², TO5 + diffusorSingle Price: 123,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with diffusor
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 180 µW/cm2
    • min. irradiance (resolution limit) is 18 nW/cm2
  • TOCON_ABC6

    TOCON_ABC6

    UVA+UVB+UVC, approx. 180 nW/cm² ... 1.8 mW/cm², TO5 + diffusorSingle Price: 123,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with diffusor
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 mW/cm2
    • min. irradiance (resolution limit) is 180 nW/cm2
  • TOCON_ABC7

    TOCON_ABC7

    UVA+UVB+UVC, approx. 1.8 µW/cm² ... 18 mW/cm², TO5 + attenuatorSingle Price: 123,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with attenuator
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 mW/cm2
    • min. irradiance (resolution limit) is 1.8 µW/cm2
  • TOCON_SI7

    TOCON_SI7

    VIS, approx. 80 lux … 80 klux, TO5 + diffusorSingle Price: 138,00€
    Product Description
    • Si based photodetector with integrated amplifier for lux measurements
    • TO5 hermetically sealed metal housing with diffusor
    • 0 … 5 V signal output
    • max. illuminance (saturation limit) at 560 nm (peak wavelength) is 80 klux
    • min. illuminance (resolution limit) is approx. 80 lux
    • ambient light measurement
  • TOCON_ABC8

    TOCON_ABC8

    UVA+UVB+UVC, approx. 18 µW/cm² ... 180 mW/cm², TO5 + attenuatorSingle Price: 123,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with attenuator
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 180 mW/cm2
    • min. irradiance (resolution limit) is 18 µW/cm2
  • TOCON_ABC9

    TOCON_ABC9

    UVA+UVB+UVC, approx. 180 µW/cm² ... 1.8 W/cm², TO5 + attenuatorSingle Price: 138,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with attenuator
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 W/cm2
    • min. irradiance (resolution limit) is 180 µW/cm2
    • UV hardening control and other very high radiation sources
  • TOCON_SI10

    TOCON_SI10

    VIS, approx. 80 klux … 80 Mlux, TO5 + attenuatorSingle Price: 138,00€
    Product Description
    • Si based photodetector with integrated amplifier for lux measurements
    • TO5 hermetically sealed metal housing with attenuator
    • 0 … 5 V signal output
    • max. illuminance (saturation limit) at 560 nm (peak wavelength) is 80 Mlux
    • min. illuminance (resolution limit) is approx. 80 klux
    • sun light measurement
  • TOCON_ABC10

    TOCON_ABC10

    UVA+UVB+UVC, approx. 1.8 mW/cm² ... 18 W/cm², TO5 + attenuatorSingle Price: 138,00€
    Product Description
    • UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
    • TO5 hermetically sealed metal housing with attenuator
    • 0 … 5 V signal output
    • max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 W/cm2
    • min. irradiance (resolution limit) is 1.8 mW/cm2
    • UV hardening control and other very high radiation sources
  • TOCON_E2

    TOCON_E2

    UVI 0...30, TO5 housing + diffusor, individual conversion factor from UV-Index to output voltage is included in the priceSingle Price: 148,00€
    Product Description
    • UV-Index photodetector with integrated amplifier
    • for UV-Index measurements up to 30 UVI, compliant to ISO 17166, measurement uncertainty less than 5%, cosine corrected
    • TO5 hermetically sealed metal housing with diffusor
    • 0 … 5 V signal output
    • 1 UVI results a voltage of approx. 170 mV
    • individual conversion factor from UV-Index to output voltage is included in the price
  • ←
  • 1
  • 2

We gladly advise you on this product

Romana Sonnenberg
Romana Sonnenberg
Dipl.-Ing.

+49 (0) 30 53015211
Tilman Weiss
Tilman Weiss
Dr.-Ing.

+49 (0) 30 53015211

Warenkorb

Accessories

  • TOCON steel housing

    TOCON steel housing

    optional probe housing for TOCON detectors, M12x1, EMC safesteel housing for all TOCONs, M12x1 threadSingle Price: 113€
    Product Description
    • steel housing for all TOCONs
    • M12x1 thread, length 32 mm
    • supply voltage 7 to 24 V
    • 0 to 5 V signal output
    • integrated sensor connector, incl. 2 m cable
  • TOCON_N steel housing

    TOCON_N steel housing

    optional probe housing for TOCON N series, M12x1, EMC safesteel housing for all TOCON N series, M12x1 threadSingle Price: 113€
    Product Description
    • steel housing for TOCON N series
    • M12x1 thread, length 39.5 mm
    • supply voltage 7 to 24 V
    • 0 to 5 V signal output
    • integrated sensor connector, incl. 2 m cable
  • TOCON PTFE housing

    TOCON PTFE housing

    optional probe housing for TOCON detectors, material PTFE, M12x1, EMC safePTFE housing for all TOCONs (except lens cap), M12x1 threadSingle Price: 113€
    Product Description
    • PTFE housing for all TOCONs (except lens cap)
    • M12x1 thread, length 31 mm
    • supply voltage 7 to 24 V
    • 0 to 5 V signal output
    • integrated sensor connector, incl. 2 m cable
  • TOCON Water PTFE Housing

    TOCON Water PTFE Housing

    optional probe housing, material PTFE, G1/4", water proof, EMC safePTFE housing for all TOCONs (except lens cap), G1/4" thread, water proofSingle Price: 113€
    Product Description
    • PTFE housing for all TOCONs (except lens cap)
    • G1/4″ thread, water proof up to 10 bar
    • supply voltage 7 to 24 V
    • 0 to 5 V signal output
    • integrated sensor connector, incl. 2 m cable
  • TOCON Water Steel Housing

    TOCON Water Steel Housing

    optional probe housing, G1/4", water proof, EMC safesteel housing for all TOCONs (except lens cap), G1/4" thread, water proofSingle Price: 113€
    Product Description
    • steel housing for all TOCONs (except lens cap)
    • G1/4″ thread, water proof up to 10 bar
    • supply voltage 7 to 24 V
    • 0 to 5 V signal output
    • integrated sensor connector, incl. 2 m cable
  • TOCON starter kit

    TOCON starter kit

    optional TOCON accessoryfor initial testing setup for all TOCON detectorsSingle Price: 20€
    Product Description
    • kit for initial testing setup
    • 0 to 5 V signal output
    • usable with all TOCON detectors

FAQ

What is a TOCON?
A TOCON is a UV photodetector that contains a SiC or a GaP detector chip and an amplifier circuit that outputs a voltage of 0 to 5 V. This output voltage is linear in proportion to the UV radiation intensity reaching the chip.
Which are the advantages and disadvantages compared with a photodiode?
Compared with a bare UV photodiode the TOCON’s big advantage is the amplifier’s position inside the TO5 metal housing and its close proximity to the detector. This construction protects the usually very low current levels generated by the detector chip from electromagnetic interference and also from moisture and pollution induced disturbances. A point to be considered of the TOCON is the lower dynamic range (approx. 3 orders of magnitude) compared with a SiC UV photodiode (10 orders of magnitude). To overdome this disadvantage we offer each TOCON type in many different amplification levels to avoid saturation and too low voltage output levels for nearly all applications.
Which are the advantages and disadvantages compared with a sensor probe?
A TOCON is smaller and much less expensive than a sensor probe. Additionally a TOCON is water pressure proof and hermetically sealed. A point to be considered is that at the presence of strong electromagnetic interferences or in case of excess voltage a sensor probe could be of a better performance. The reason is that a sensor probe contains more space that is needed for components that avoid problems caused by ESD or excess voltage.
Is the TOCON calibrated?
No, the TOCON is not calibrated. If required, the sglux calibration laboratory offers an individual calibration service including a calibration certificate. This document assigns the voltage output of one specific TOCON to the irradiation of a specific UV radiation source. As-delivered the TOCON is sensitive in the specified range. Example: A TOCON_ABC6 is sensitive between 180 nW/cm² and 1.8 mW/cm². This means that the TOCON will saturate (output voltage = input voltage) at approx. 1.8 mW/cm². At the lower end a radiation of 180 nW/cm² will still output a couple of mV. While selecting a TOCON, the most important thing to consider is to not illuminate the TOCON until saturation level. A saturation will not damage the TOCON but likely the voltage output will no longer be linear to the radiation input because any increase of radiation below the saturation point will not further increase the output voltage.
What is the maximum signal output of a TOCON?
The theoretical maximum signal output is always a little less (approx. 5%) than the supply voltage.
Do I need an external amplifier?
No, no additional amplifier is required.
How can I use my TOCON?
Please use a standard voltmeter to read out the signal. Caution! Wrong wiring of power supply can lead to immediate destruction of the device. Please refer to our application note delivered with the device.
What about the TOCON scatter?
A TOCON is a sophisticated product with many internal components. Many of these internal components, and especially the quantum efficiency of the UV-sensing SiC chip and the gain resistor value, have sample to sample scatter (variation). TOCONs are designed for a total scatter of +/-20% in signal and some devices will show greater variance. It is recommended that that when choosing a TOCON model for production, the TOCON should be chosen so that the 5V saturation level is TWICE the expected signal from the device under normal conditions and that under normal/design conditions, output voltage is about 2.5V. Customers are especially cautioned to AVOID SATURATION conditions. Saturation is when Signal voltage equals Power Supply Voltage (normally 5V). Saturation will not damage the TOCON but it can lead to PERSONAL SAFETY PROBLEMS or other DAMAGE due to unknown and potentially excess UV exposure levels.
What is the output pin impedance (or the drive capability) of the TOCON sensor?
The TOCON can drive resistive loads as low as 2 kOhms, but we recommend not to stress this limit unnecessarily. In normal environments an input impedance of >= 100 kOhm is recommended for the readout circuitry. In very harsh (EMI/EMC/noisy) surroundings impedances of >= 10 kOhm can be considered taking into account a slight reduction in output swing. The TOCON is stable for capacitive loads up to 30 pF under all circumstances. If more capacitive loading can not be avoided a series resistor of 10 Ohms … 100 Ohms may be required to ensure stability up to few hundred nF.
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Imprint Privacy policy LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy