Galliumphosphide (GaP)
spectral sensitivity from 240 to 560 nm, peak wavelength 445 nm,
for UV + VIS measurements, sorted by irradiance.
Showing all 6 results
- 
	

TOCON_GAP4
GAP, approx. 0.9 nW/cm² ... 9 µW/cm², TO5 + diffusorProduct Description- GaP photodetector with integrated amplifier
 - for UV + VIS (240 – 590 nm) measurements
 - TO5 hermetically sealed metal housing with diffusor
 - 0 … 5 V signal output
 - max. irradiance (saturation limit) at 445 nm (peak wavelength) is 9 µW/cm2
 - min. irradiance (resolution limit) is 0.9 nW/cm2
 
 - 
	

TOCON_GAP5
GAP, approx. 9 nW/cm² ... 90 µW/cm², TO5 + diffusorProduct Description- GaP photodetector with integrated amplifier
 - for UV + VIS (240 – 560 nm) measurements
 - TO5 hermetically sealed metal housing with diffusor
 - 0 … 5 V signal output
 - max. irradiance (saturation limit) at 445 nm (peak wavelength) is 90 µW/cm2
 - min. irradiance (resolution limit) is 9 nW/cm2
 
 - 
	

TOCON_GAP6
GAP, approx. 90 nW/cm² ... 900 µW/cm², TO5 + diffusorProduct Description- GaP photodetector with integrated amplifier
 - for UV + VIS (240 – 560 nm) measurements
 - TO5 hermetically sealed metal housing with diffusor
 - 0 … 5 V signal output
 - max. irradiance (saturation limit) at 445 nm (peak wavelength) is 900 µW/cm2
 - min. irradiance (resolution limit) is 90 nW/cm2
 
 - 
	

TOCON_GAP7
GAP, approx. 900 nW/cm² ... 9 mW/cm², TO5 + diffusorProduct Description- GaP photodetector with integrated amplifier
 - for UV + VIS (240 – 560 nm) measurements
 - TO5 hermetically sealed metal housing with diffusor
 - 0 … 5 V signal output
 - max. irradiance (saturation limit) at 445 nm (peak wavelength) is 9 mW/cm2
 - min. irradiance (resolution limit) is 900 nW/cm2
 
 - 
	

TOCON_GAP8
GAP, approx. 9 µW/cm² ... 90 mW/cm², TO5 + diffusorProduct Description- GaP photodetector with integrated amplifier
 - for UV + VIS (240 – 560 nm) measurements
 - TO5 hermetically sealed metal housing with diffusor
 - 0 … 5 V signal output
 - max. irradiance (saturation limit) at 445 nm (peak wavelength) is 90 mW/cm2
 - min. irradiance (resolution limit) is 9 µW/cm2
 
 - 
	

TOCON_GAP9
GAP, approx. 90 µW/cm² ... 900 mW/cm², TO5 + diffusorProduct Description- GaP photodetector with integrated amplifier
 - for UV + VIS (240 – 560 nm) measurements
 - TO5 hermetically sealed metal housing with diffusor
 - 0 … 5 V signal output
 - max. irradiance (saturation limit) at 445 nm (peak wavelength) is 900 mW/cm2
 - min. irradiance (resolution limit) is 90 µW/cm2
 
 