Blue light
spectral sensitivity from 390 to 515 nm, peak wavelength 445 nm,
for blue light measurements, sorted by irradiance.
Showing all 6 results
-
TOCON_BLUE4
blue light, approx. 0.9 nW/cm² ... 9 µW/cm², TO5Product Description- GaP photodetector with integrated amplifier
- measurement of blue light (approx. 400…500nm) according to guideline 2006/25/EC
(Limits on exposure to artificial optical radiation) - TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 445 nm is 9 µW/cm2
- min. irradiance (resolution limit) is 0.9 nW/cm2
-
TOCON_BLUE5
blue light, approx. 9 nW/cm² ... 90 µW/cm², TO5Product Description- GaP photodetector with integrated amplifier
- measurement of blue light (approx. 400…500nm) according to guideline 2006/25/EC
(Limits on exposure to artificial optical radiation) - TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 445 nm is 90 µW/cm2
- min. irradiance (resolution limit) is 9 nW/cm2
-
TOCON_BLUE6
blue light, approx. 90 nW/cm² ... 900 µW/cm², TO5Product Description- GaP photodetector with integrated amplifier
- measurement of blue light (approx. 400…500nm) according to guideline 2006/25/EC
(Limits on exposure to artificial optical radiation) - TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 445 nm is 900 µW/cm2
- min. irradiance (resolution limit) is 90 nW/cm2
-
TOCON_BLUE7
blue light, approx. 900 nW/cm² ... 9 mW/cm², TO5Product Description- GaP photodetector with integrated amplifier
- measurement of blue light (approx. 400…500nm) according to guideline 2006/25/EC
(Limits on exposure to artificial optical radiation) - TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 445 nm is 9 mW/cm2
- min. irradiance (resolution limit) is 900 nW/cm2
-
TOCON_BLUE8
blue light, approx. 9 µW/cm² ... 90 mW/cm², TO5Product Description- GaP photodetector with integrated amplifier
- measurement of blue light (approx. 400…500nm) according to guideline 2006/25/EC
(Limits on exposure to artificial optical radiation) - TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 445 nm is 90 mW/cm2
- min. irradiance (resolution limit) is 9 µW/cm2
-
TOCON_BLUE9
blue light, approx. 90 µW/cm² ... 900 mW/cm², TO5Product Description- GaP photodetector with integrated amplifier
- measurement of blue light (approx. 400…500nm) according to guideline 2006/25/EC
(Limits on exposure to artificial optical radiation) - TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 445 nm is 900 mW/cm2
- min. irradiance (resolution limit) is 90 µW/cm2