sglux-logo
bag-icon
Generic filters
Exact matches only
en
  • Shop
    • UV Photodiodes
    • UV TOCONs
      Photodiodes with integrated signal amplifier
    • UV Sensors
    • UV Radiometers
    • Customized solutions
    • UV Calibration
    • UV Index Measurement
    • Transducers for photodiodes
  • sglux ESG concept
  • Research
  • About Us
  • Contact Us
    • Distributors
    • Privacy Policy
    • Imprint
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Research
  • About Us
  • Contact Us

2022 – How to determine the right UV sensor for flame detection?

23. May 2022 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

How to determine the right UV sensor for flame detection?

Abstract
The present article informs about different approaches using UV photodetectors for the detection of a combustion flame (natural gas, hydrogen or oil).

Filed Under: publications and reports, Research Tagged With: customized, flame, general, irradiance_all

2022 – Marker Substances in the Aroma of Truffles

23. May 2022 von sglux

Ruben Epping¹, Lilly Bliesener¹, Dr. Tilman Weiss², Matthias Koch¹, *
¹Division of Organic Trace Analysis and Food Analysis, Bundesanstalt für Materialforschung und -Prüfung, Berlin, Germany
²sglux GmbH, Berlin, Germany
*Authors to whom correspondence should be addressed.

Marker Substances in the Aroma of Truffles

Abstract
The aim of this study was to identify specific truffle marker substances within the truffle aroma. The aroma profile of different truffle species was analyzed using static headspace sampling with gas chromatography mass spectrometry analysis (SHS/GC-MS). Possible marker substances were identified, taking the additional literature into account. The selected marker substances were tested in an experiment with 19 truffle dogs. The hypothesis “If trained truffle dogs recognize the substances as supposed truffles in the context of an experiment, they can be regarded as specific” was made. As it would be nearly impossible to investigate every other possible emitter of the same compounds to determine their specificity, this hypothesis was a reasonable approximation. We were interested in the question of what it is the dogs actually search for on a chemical level and whether we can link their ability to find truffles to one or more specific marker substances. The results of the dog experiment are not as unambiguous as could have been expected based on the SHS/GC-MS measurements. Presumably, the truffle aroma is mainly characterized and perceived by dogs by dimethyl sulfide and dimethyl disulfide. However, as dogs are living beings and not analytical instruments, it seems unavoidable that one must live with some degree of uncertainty regarding these results.

Filed Under: publications and reports, Research Tagged With: customized, fluorescence, gap, irradiance_lo, science, truffles

TOCONs with reduced dead times used for the detection of fire and combustion burner flames

30. November 2021 von sglux

Further information can be found in our publication:
TOCONs for the detection of fire and combustion burner flames

Filed Under: Research Tagged With: Feuererkennung, flame, flame_detection

2021 – How two sglux photodiodes contribute to the NASA 2021 Perseverance mission

30. November 2021 von sglux

Luther W. Beegle et al.
Space Sci Rev (2021) 217:58

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

Abstract
The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Labora- tory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are natu- rally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Aut- ofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spa- tial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7×7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which sam- ples to collect and cache for Mars sample return.

Filed Under: publications and reports, Research Tagged With: irradiance_all, photodiodes, science, UVI

2021 – Sensing ultraviolet light emission from hydrogen flames: Flame detection and flame monitoring in CO2 emission free domestic boilers

23. May 2021 von sglux

Bielefeld, S.E., TU Delft Electrical Engineering, Mathematics and Computer Science


Master Thesis

Abstract
As a contribution to the decarbonisation of domestic heating, the graduation project investigates the feasibility of the application of UV sensor technology for flame detection and flame monitoring in hydrogen-powered domestic gas boilers. The research includes empirical studies and an analytical approach to describe influences on the sensor signal strength.

Filed Under: publications and reports, Research Tagged With: flame, hydrogen, irradiance_lo, prod, stability

2021 – TOCONs with reduced dead times used for the detection of fire and combustion burner flames

5. May 2021 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

TOCONs for the detection of fire and combustion burner flames

Abstract
The standard sglux TOCONs are featured by a relatively high time constant that extends from 30 ms (low sensitivity TOCONs) until 80 ms (high sensitivity TOCONs). Most of the TOCON applications benefit from this high time constant because usually the TOCON’s application is to measure a UV irradiation that slowly changes. Such applications are e.g. the control of UV disinfection and UV curing sources. Short changes of signal caused by electromagnetic or high frequency influences are averaged – which is a benefit. However, looking at flame detection in heaters or looking at fire detection applications this relatively high time constant may cause problems. The present report presents opportunities to reduce the dead time of the TOCONs.

Filed Under: publications and reports, Research Tagged With: Feuererkennung, flame, flame_detection, hydrogen, irradiance_lo, önorm, prod

2016-2021 – Investigation of UV-Aging behavior of components used in the production of UV-LEDs and UV-Sensors.

5. May 2021 von sglux

Partner: sglux GmbH
Research project within the 20zwanzig initiative “Advanced UV for life”
period: 2016 – 2021
acknowledgements: BMBF 03ZZ0123

Abstract
Within the UV-Aging project experimental setups and scientific method are developed to allow a reliable estimation of the degradation behavior of LED and photodiodes as well as components used in these products (glass, diffusors, reflectors, glues, etc.). In the beginning a UV-Aging chamber will be constructed which allows the control of UV light (UV-A, B & C), temperature (up to 170°C) and humidity (95% r.h.).

Filed Under: completed projects, Research

2020 – UV sensors to control UVC surface disinfection

5. October 2020 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

UV sensors to control UVC surface disinfection

Abstract
Besides chemical treatment, UVC sterilization is applied to disinfect air and tools in hospitals, doctor’s offices, pharmacies as well as food and pharmaceutical production facilities and public washrooms. These applications require measurements of the UV radiation either at its place of generation or at the position of the goods to be disinfected. This procedure is crucial to ensure that a sufficient germ killing UV dose hits the goods. The report presents further details and suitable sensor and radiometer products.

Filed Under: publications and reports, Research Tagged With: diffuser, irradiance_hi, prod, sensors, surface

2020 – Where SiC can replace discontinued GaP?

23. May 2020 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

Technical Report “Where SiC can replace discontinued GaP?”

Abstract
For measurement applications with a peak radiation between 210 nm and 346 nm (e.g. UV sterilization lamp or combustion flame control) a SiC UV photodiode can replace a GaP photodiode without restrictions – it will even output a higher photocurrent. A SiC device irradiated with a peak radiation from 346 to 380 nm will output a lower photocurrent compared with GaP (at same active area). However, if the radiation intensity is high, e.g. curing applications at 365 nm the SiC’s current output will remain at a usable level.

Filed Under: publications and reports, Research

2020 – Temperature Coefficient of SiC UV Photodiodes

23. May 2020 von sglux

Stefan Langer, sglux GmbH, Berlin, Germany

SiC Temperature Coefficient

Abstract
This report assigns the temperature coefficient (TC) of sglux SiC-photodiodes in relation to the incident wavelength. It demonstrates that the temperature coefficient is slightly negative for incident wavelengths below 270nm. At appox. 270nm is it almost zero and then strongly rises towards positive values with increasing wavelengths. The report further explains the physical background of this phenomena.

Filed Under: publications and reports, Research

  • « Previous Page
  • 1
  • 2
  • 3
  • 4
  • 5
  • Next Page »

Address

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Germany
Tel: +49 (0) 30 53 01 52 11
Mail:

sglux delivers worldwide

Alternatively we are represented by our global sales partners FARNELL and DISTRELEC which cover more than 80 countries.

In your region the below listed Specialists distribute our products and provide further expertly assistance to find the best solution for your UV measurement work - almost round the clock.

Distributors
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Imprint Privacy policy LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy