sglux-logo
bag-icon
Generic filters
Exact matches only
en
  • Shop
    • UV Photodiodes
    • UV TOCONs
      Photodiodes with integrated signal amplifier
    • UV Sensors
    • UV Radiometers
    • Customized solutions
    • UV Calibration
    • UV Index Measurement
    • Transducers for photodiodes
  • sglux ESG concept
  • Research
  • About Us
  • Contact Us
    • Distributors
    • Privacy Policy
    • Imprint
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Research
  • About Us
  • Contact Us

2023 – Approaches of LED in-line measurements and its traceable calibration

23. May 2023 von sglux

Gabriel Hopfenmüller, Dr. Niklas Papathanasiou, sglux GmbH, Berlin, Germany

InterAqua Japan 01. – 03.02.2023
Approaches of LED in-line measurements and its traceable calibration

Abstract
UV measurement at UV LED arrays.

Filed Under: publications and reports, Research Tagged With: calibration, irradiance_all, led, prod, VUV

2013 – Developing and setting up a calibration facility for UV sensors at high irradiance rates

23. May 2013 von sglux

B. Barton¹, P. Sperfeld¹, A. Towara¹, G. Hopfenmueller²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Abstract
PTB provides spectral irradiance calibrations traceable to national primary standards and the SI system. A transfer standard source for high UV irradiances has been constructed and characterized. A medium pressure Hg lamp and a low pressure Hg lamp provide different spectra at different irradiance levels. The system might serve as a calibration facility for DVGW & ÖNORM conform UV sensors. Calibration by direct substitution to reference sensors can be carried out.

Filed Under: publications and reports, Research Tagged With: calibration, irradiance_hi, önorm, science

2013 – Traceable spectral irradiance measurements at UV water disinfection plants

23. May 2013 von sglux

P. Sperfeld¹, B. Barton¹, S. Pape¹, G. Hopfenmueller²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Abstract
PTB provides spectral irradiance calibrations traceable to national primary standards and the SI system. Transportable spectroradiometer systems have been adapted for high UV irradiance measurements. Successful measurements at medium pressure Hg and low pressure Hg lamp facilities have been carried out. The effective microbicidal irradiances agree within 15%. 40° sensor geometry could be developed. Discussion about calibration service and support.

Filed Under: publications and reports, Research Tagged With: calibration, irradiance_hi, önorm, science

2013 – PTB traceable calibrated reference UV radiometer for measurements at high irradiance medium pressure mercury discharge lamps

23. May 2013 von sglux

G. Hopfenmueller¹, T.Weiss¹, B. Barton², P. Sperfeld², S. Nowy², S. Pape², D. Friedrich², S. Winter², A. Towara², A. Hoepe², S. Teichert²,
¹sglux GmbH, Berlin, Germany, ²Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Filed Under: publications and reports, Research Tagged With: calibration, irradiance_hi, önorm, science

2012 – Highly reliable Silicon Carbide photodiodes for visible-blind ultraviolet detector applications

23. May 2012 von sglux

D. Prasai¹, W. John¹, L. Weixelbaum¹, O. Krueger¹, G. Wagner², P. Sperfeld³, S. Nowy³, D. Friedrich³, S. Winter³ and T. Weiss⁴,
¹Ferdinand-Braun-Institut, Leibniz-Institut fuer Hoechstfrequenztechnik, Berlin, Germany, ²Leibniz-Institut fuer Kristallzuechtung, Berlin, Germany, ³Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ⁴sglux GmbH, Berlin, Germany

J. Mater. Res., first view (2012).

Abstract
Highly efficient polytype 4H silicon carbide (4H-SiC) p–n diodes for ultraviolet (UV) light detection have been fabricated, characterized, and exposed to high-intensity mercury lamp irradiation (up to 17 mW/cm²). The behavior of the photocurrent response under UV light irradiation using a low-pressure mercury UV-C lamp (4 mW/cm²) and a medium-pressure mercury discharge lamp (17 mW/cm²) has been studied. We report on long-term UV photoaging tests performed for up to 22 mo. Results demonstrate the robustness of SiC photodiodes against UV radiation. The devices under test showed an initial burn-in effect, i.e., the photocurrent response dropped by less than 5% within the first 40 h of artificial UV aging. Such burn-in effect under UV stress was also observed for previously available polytype 6H silicon carbide (6H–SiC) p–n photodetectors. After burn-in, no measurable degradation has been detected, which makes the devices excellent candidates for high irradiance UV detector applications.

Filed Under: publications and reports, Research Tagged With: calibration, irradiance_all, photodiodes, prod

Address

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Germany
Tel: +49 (0) 30 53 01 52 11
Mail:

sglux delivers worldwide

Alternatively we are represented by our global sales partners FARNELL and DISTRELEC which cover more than 80 countries.

In your region the below listed Specialists distribute our products and provide further expertly assistance to find the best solution for your UV measurement work - almost round the clock.

Distributors
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Imprint Privacy policy LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies