TOCONs for flame and fire detection
TOCONs for flame detection in burners operated with natural gas, heating oil, or hydrogen, as well as TOCONs for fire detection
Showing all 5 results
-
TOCON_F
UVA+UVB+UVC, approx. 0.05 nW/mm² ... 10 nW/mm², TO5 lens cap, hydrogen flame detection Product Description- UV broadband (UVA+UVB+UVC) photodetector with integrated logarithmic amplifier, linear measuring range up to 2,100 mV through the use of a SiC junction diode
- TO5 hermetically sealed metal housing with lens cap
- designed for hydrogen flame detection according to EN298
- 0…3V – signal output
- typical irradiation intensity 0.05 nW/mm²…10 nW/mm²
- replacement for UV sensor SFH530 and UVTRON tubes
- for evaluation purposes several housing options are available on request
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC1
UVA+UVB+UVC, approx. 1.8 pW/cm² ... 18 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- detection of hydrocarbon fuel flames and hydrogen flames according to EN298
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 18 nW/cm2
- min. irradiance (resolution limit) is 1.8 pW/cm2
- replaces obsolete Perkin Elmer UV10.T2E.10L and UV10.SF
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC2
UVA+UVB+UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- detection of hydrocarbon fuel flames and hydrogen flames according to EN298
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 180 nW/cm2
- min. irradiance (resolution limit) is 18 pW/cm2
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_C1
UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5 housing without diffusorProduct Description- UVC photodetector with integrated amplifier
- large 1 mm² SiC detector chip to maximize sensitivity
- TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 254 nm is 180 nW/cm2
- min. irradiance (resolution limit) is 18 pW/cm2
-
TOCON_NC1F
UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5, fire detection, fast response time, TO5 housing with diffusorProduct Description- UVC photodetector with integrated amplifier
- with fast response time for fire detection
- large 1 mm² SiC detector chip to maximize sensitivity
- with diffusor for broadening of the field of view
- TO5 hermetically sealed metal housing
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 254 nm is 180 nW/cm2
- min. irradiance (resolution limit) is 18 pW/cm2
- This TOCON needs a positive and a negative power supply. For product evaluation the TOCON_N_steel housing with integrated bias generator is available.
- replacement for discharge flame sensors