UV TOCONs
- SiC based UV sensor with integrated amplifier and 0 – 5 V voltage output
- Measures intensities from 1.8pW/cm² up to 18W/cm²
- Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index
- Also available for blue light (GaP chip) or visible light (Si chip) measurement.
- Available in TO5 housings or as miniature sensor probes (stainless steel or plastic).
- Special TOCONs for hydrogen flame sensing (TOCON_F) and for fire detection (TOCON_N) available.
- Also available for operating temperatures up to 120°C (standard is 85°C).
- Please learn more about the sglux TOCONs here: TOCON selection guide and here: TOCON User Guide.
All TOCONs are always on stock, no minimum order quantity. They can be ordered via our web shop or with an email addressed to welcome@sglux.de. Alternatively, we are happy to issue a quotastion or you may click on our shop’s QUOTATION function, instead of CHECKOUT.
Showing 31–48 of 48 results
-
TOCON_A7
UVA, approx. 1.8 µW/cm² ... 18 mW/cm², TO5 + attenuatorProduct Description- UVA photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 331 nm (peak wavelength) is approx. 18 mW/cm2
- min. irradiance (resolution limit) is 1.8 µW/cm2
-
TOCON_A8
UVA, approx. 18 µW/cm² ... 180 mW/cm², TO5 + attenuatorProduct Description- UVA photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 331 nm (peak wavelength) is approx. 180 mW/cm2
- min. irradiance (resolution limit) is 18 µW/cm2
-
TOCON_A9
UVA, approx. 100 µW/cm² ... 1.0 W/cm², TO5 + attenuatorProduct Description- UVA photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 331 nm (peak wavelength) is approx. 1.0 W/cm2
- min. irradiance (resolution limit) is 100 µW/cm2
-
TOCON_F
UVA+UVB+UVC, approx. 0.05 nW/mm² ... 10 nW/mm², TO5 lens cap, hydrogen flame detection Product Description- UV broadband (UVA+UVB+UVC) photodetector with integrated logarithmic amplifier,linear measuring range up to 2,100 mV through the use of a SiC junction diode
- TO5 hermetically sealed metal housing with lens cap
- designed for hydrogen flame detection according to EN298
- 0…3V – signal output, also available with 4…20mA current loop
- typical irradiation intensity 0.05 nW/mm²…10 nW/mm²
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC1
UVA+UVB+UVC, approx. 1.8 pW/cm² ... 18 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- detection of hydrocarbon fuel flames and hydrogen flames according to EN298
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 18 nW/cm2
- min. irradiance (resolution limit) is 1.8 pW/cm2
- replaces obsolete Perkin Elmer UV10.T2E.10L and UV10.SF
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_SI1
VIS, approx. 80 µlux … 80 mlux, TO5 lens capProduct Description- Si based photodetector with integrated amplifier for lux measurements
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. illuminance (saturation limit) at 560 nm (peak wavelength) is 80 mlux
- min. illuminance (resolution limit) is approx. 80 µlux
- for very low illuminance measurement such as stray light detection
-
TOCON_ABC2
UVA+UVB+UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- detection of hydrocarbon fuel flames and hydrogen flames according to EN298
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 180 nW/cm2
- min. irradiance (resolution limit) is 18 pW/cm2
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC3
UVA+UVB+UVC, approx. 180 pW/cm² ... 1.80 µW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 µW/cm2
- min. irradiance (resolution limit) is 180 pW/cm2
-
TOCON_ABC4
UVA+UVB+UVC, approx. 1.8 nW/cm² ... 18 µW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 µW/cm2
- min. irradiance (resolution limit) is 1.8 nW/cm2
-
TOCON_ABC5
UVA+UVB+UVC, approx. 18 nW/cm² ... 180 µW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 180 µW/cm2
- min. irradiance (resolution limit) is 18 nW/cm2
-
TOCON_ABC6
UVA+UVB+UVC, approx. 180 nW/cm² ... 1.8 mW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 mW/cm2
- min. irradiance (resolution limit) is 180 nW/cm2
-
TOCON_ABC7
UVA+UVB+UVC, approx. 1.8 µW/cm² ... 18 mW/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 mW/cm2
- min. irradiance (resolution limit) is 1.8 µW/cm2
-
TOCON_SI7
VIS, approx. 80 lux … 80 klux, TO5 + diffusorProduct Description- Si based photodetector with integrated amplifier for lux measurements
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. illuminance (saturation limit) at 560 nm (peak wavelength) is 80 klux
- min. illuminance (resolution limit) is approx. 80 lux
- ambient light measurement
-
TOCON_ABC8
UVA+UVB+UVC, approx. 18 µW/cm² ... 180 mW/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 180 mW/cm2
- min. irradiance (resolution limit) is 18 µW/cm2
-
TOCON_ABC9
UVA+UVB+UVC, approx. 180 µW/cm² ... 1.8 W/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 W/cm2
- min. irradiance (resolution limit) is 180 µW/cm2
- UV hardening control and other very high radiation sources
-
TOCON_SI10
VIS, approx. 80 klux … 80 Mlux, TO5 + attenuatorProduct Description- Si based photodetector with integrated amplifier for lux measurements
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. illuminance (saturation limit) at 560 nm (peak wavelength) is 80 Mlux
- min. illuminance (resolution limit) is approx. 80 klux
- sun light measurement
-
TOCON_ABC10
UVA+UVB+UVC, approx. 1.8 mW/cm² ... 18 W/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 W/cm2
- min. irradiance (resolution limit) is 1.8 mW/cm2
- UV hardening control and other very high radiation sources
-
TOCON_E2
UVI 0...30, TO5 housing + diffusor, individual conversion factor from UV-Index to output voltage is included in the priceProduct Description- UV-Index photodetector with integrated amplifier
- for UV-Index measurements up to 30 UVI, compliant to ISO 17166, measurement uncertainty less than 5%, cosine corrected
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- 1 UVI results a voltage of approx. 170 mV
- individual conversion factor from UV-Index to output voltage is included in the price