Broadband UV
spectral sensitivity from 227 to 360 nm, peak wavelength 290 nm,
sorted by irradiance.
Showing all 11 results
-
TOCON_F
UVA+UVB+UVC, approx. 0.05 nW/mm² ... 10 nW/mm², TO5 lens cap, hydrogen flame detection Product Description- UV broadband (UVA+UVB+UVC) photodetector with integrated logarithmic amplifier,linear measuring range up to 2,100 mV through the use of a SiC junction diode
- TO5 hermetically sealed metal housing with lens cap
- designed for hydrogen flame detection according to EN298
- 0…3V – signal output, also available with 4…20mA current loop
- typical irradiation intensity 0.05 nW/mm²…10 nW/mm²
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC1
UVA+UVB+UVC, approx. 1.8 pW/cm² ... 18 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- detection of hydrocarbon fuel flames and hydrogen flames according to EN298
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 18 nW/cm2
- min. irradiance (resolution limit) is 1.8 pW/cm2
- replaces obsolete Perkin Elmer UV10.T2E.10L and UV10.SF
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC2
UVA+UVB+UVC, approx. 18 pW/cm² ... 180 nW/cm², TO5 lens cap, detection of hydrocarbon fuel flames and hydrogen flamesProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- detection of hydrocarbon fuel flames and hydrogen flames according to EN298
- TO5 hermetically sealed metal housing with lens cap
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 280 nm (peak wavelength) is approx. 180 nW/cm2
- min. irradiance (resolution limit) is 18 pW/cm2
- replacement for discharge flame sensors
- We are happy to support your Failure Mode and Effects Analysis (FMEA). Please contact us.
-
TOCON_ABC3
UVA+UVB+UVC, approx. 180 pW/cm² ... 1.80 µW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 µW/cm2
- min. irradiance (resolution limit) is 180 pW/cm2
-
TOCON_ABC4
UVA+UVB+UVC, approx. 1.8 nW/cm² ... 18 µW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 µW/cm2
- min. irradiance (resolution limit) is 1.8 nW/cm2
-
TOCON_ABC5
UVA+UVB+UVC, approx. 18 nW/cm² ... 180 µW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 180 µW/cm2
- min. irradiance (resolution limit) is 18 nW/cm2
-
TOCON_ABC6
UVA+UVB+UVC, approx. 180 nW/cm² ... 1.8 mW/cm², TO5 + diffusorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with diffusor
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 mW/cm2
- min. irradiance (resolution limit) is 180 nW/cm2
-
TOCON_ABC7
UVA+UVB+UVC, approx. 1.8 µW/cm² ... 18 mW/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 mW/cm2
- min. irradiance (resolution limit) is 1.8 µW/cm2
-
TOCON_ABC8
UVA+UVB+UVC, approx. 18 µW/cm² ... 180 mW/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 180 mW/cm2
- min. irradiance (resolution limit) is 18 µW/cm2
-
TOCON_ABC9
UVA+UVB+UVC, approx. 180 µW/cm² ... 1.8 W/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 1.8 W/cm2
- min. irradiance (resolution limit) is 180 µW/cm2
- UV hardening control and other very high radiation sources
-
TOCON_ABC10
UVA+UVB+UVC, approx. 1.8 mW/cm² ... 18 W/cm², TO5 + attenuatorProduct Description- UV broadband (UVA+UVB+UVC) photodetector with integrated amplifier
- TO5 hermetically sealed metal housing with attenuator
- 0 … 5 V signal output
- max. irradiance (saturation limit) at 290 nm (peak wavelength) is approx. 18 W/cm2
- min. irradiance (resolution limit) is 1.8 mW/cm2
- UV hardening control and other very high radiation sources