2020 – Temperature Coefficient of SiC UV Photodiodes

23. May 2020 von sglux

Stefan Langer, sglux GmbH, Berlin, Germany

SiC Temperature Coefficient

Abstract
This report assigns the temperature coefficient (TC) of sglux SiC-photodiodes in relation to the incident wavelength. It demonstrates that the temperature coefficient is slightly negative for incident wavelengths below 270nm. At appox. 270nm is it almost zero and then strongly rises towards positive values with increasing wavelengths. The report further explains the physical background of this phenomena.

Filed Under: publications and reports, Research

Address

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Germany
Tel: +49 (0) 30 53 01 52 11
Mail:

sglux delivers worldwide

Alternatively we are represented by our global sales partners FARNELL and DISTRELEC which cover more than 80 countries.

In your region the below listed Specialists distribute our products and provide further expertly assistance to find the best solution for your UV measurement work - almost round the clock.

Distributors
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Imprint Privacy policy LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies