2024 – Digital UV Sensors simplify measurement and control

23. julio 2024 von sglux

Dr. Tilman Weiss¹, Fred Perry²
¹sglux GmbH, Berlin, Germany
²Boston Electronics Corporation, Brookline, USA

Journal Contribution to the IUVA UV Solutions Magazine (c) IUVA

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: digiprobe, irradiance_all, prod, radiometer, sensors

2024 – UV-Strahlung messen ohne Filter – Siliziumcarbid (SiC) – Photodioden machen’s möglich

1. febrero 2024 von sglux

Dr. Niklas Papathanasiou, sglux GmbH, Berlin, Germany

Sensor Magazin 2/2024 (c) Magazin Verlag

Zusammenfassung
Das Berliner Unternehmen sglux GmbH produziert seit mehr als 20 Jahren Photodioden und Sensoren zur Messung von UV-Strahlung, wie sie in vielen Bereichen der industriellen Fertigung, der Medizintechnik, der Feuerungstechnik und zur Entkeimungsüberwachung zum Einsatz kommen. Die präzise Erfassung der ultravioletten Bestrahlungsstärke ist für eine kontrollierte und effiziente Funktionsweise von hoher Bedeutung. sglux löst diese Aufgaben mit SiC-basierten Photodioden, seit 2009 aus eigener Halbleiterproduktion. Bei der Detektion von UV-Strahlung sind SiC-Photodioden aufgrund ihrer hohen Bandlücke von 3.26 eV im Vorteil, da sie gegenüber sichtbarer und nah-infraroter Strahlung blind sind. Zudem weisen SiC-Photodioden sehr niedrige Dunkelströme auf, sodass auch kleinste Strahlungsmengen nachgewiesen werden können. Im Bereich der Messung starker UV-Strahlung punktet SiC mit seiner hohen Degradationsfestigkeit.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: general, irradiance_all, photodiodes, sensors

2020 – UV-Sensoren zur Überwachung der UVC-Oberflächenentkeimung

5. octubre 2020 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

UV-Sensoren zur Überwachung der UVC-Oberflächenentkeimung

Zusammenfassung
Bei der Entkeimung von Oberflächen in Artzpraxen, Krankenzimmern, Apotheken aber auch in der Lebensmittel- und Medikamentenproduktion sowie öffentlich zugänglichen Sanitärbereichen kommt neben chemischen Verfahren auch UVC-Strahlung zum Einsatz. Bei diesen Anwendungen ist die UV-Strahlung entweder am Ort der Erzeugung oder am Wirkort oder an beiden Orten zu erfassen. So kann die zur sicheren Keimabtötung mindestens erforderliche Dosis hinreichend genau ermittelt werden. Der Bericht liefert weitere Details und stellt geeignete Mess-Produkte aus dem sglux-Sortiment vor.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: diffuser, irradiance_hi, prod, sensors, surface

2017 – Degradation of opaque quartz-glass diffusers under high intensity UV irradiation

1. octubre 2017 von sglux

N. Papathanasiou, G. Hopfenmüller, Michael Matalla, T. Weiss,
sglux GmbH, Berlin, Germany

Presentation on IUVA World Congress Spotlights Water Disinfection Technologies 2017, Dubrovnik, Croatia

Abstract
In UV water purification applications UV sensors are monitoring the dosage of UV irradiation as according to ÖNORM and DVGW standards. sglux GmbH is manufacturing such sensors employing opaque synthetic quartz-glass diffusers as entrance windows. This paper investigates the influence of high-intensity UV irradiation on the transmission behavior of these diffusers. Quartz-glass and micro-porous quartz-glass were investigated. The sensors were continuously monitored while irradiated by a 1kW medium pressure Hg lamp with a total UV irradiance of 1000mW/cm² for 800 hours. Before and after the aging period the total transmissions of the diffusers were measured.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: diffuser, irradiance_hi, science, sensors, stability

2011 – Characterisation of new optical diffusers used in high irradiance UV radiometers

23. noviembre 2011 von sglux

Barton¹, B., Sperfeld¹, P., Nowy¹, S., Towara¹, A., Hoepe¹, A., Teichert¹, S., Hopfenmueller², G., Baer³, M. and Kreuzberger³, T.
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany, ³SGIL Silicaglas GmbH, Langewiesen, Germany

Proceedings of NEWRAD2011, edited by S. Park and E. Ikonen. (Aalto University, Espoo, Finland, 2011) p. 278.

Abstract
Diffusers are essential components of UV radiometers used as transfer standards. They improve the insensitivity to differing radiation situations. In combination with a beam limiting aperture, a diffuser defines the irradiated area [1]. A detailed study of different properties of UV diffusers is shown.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: curing, diffuser, irradiance_hi, science, sensors

Dirección

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Alemania
Tel: +49 (0) 30 53 01 52 11
Fax: +49 (0) 30 53 01 52 09
Mail:

sglux suministra en todo el mundo

Como alternativa, somos representados a través de nuestros distribuidores mundiales FARNELL y GERHARD en más de 80 países.

En su región, los siguientes especialistas distribuyen nuestros productos y proporcionan asesoramiento profesional para encontrar la mejor solución en su trabajo de medición UV (casi) todo el día:

Distribuidores
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Aviso legal Politica de privacidad LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies