2019 – UV degradation anaylsis of SiC and AlGaN based UV photodiodes

23. mai 2025 von sglux

Dr. Niklas Papathanasiou, sglux GmbH, Berlin, Germany

SiC AlGaN Aging Report

Zusammenfassung
SiC and AlGaN based UV photodiodes had been irradiated by Hg medium pressure lamps for 90 hours and a UV irradiation intensity of 60mW/cm². The SiC photodiodes showed no measurable degradation whereas the AlGaN photodiodes lost 80 % – 85 % of sensitivity.

Classé sous :Forschung, Veröffentlichungen und Berichte Balisé avec :irradiance_hi, led, photodiodes, science, stability

2021 – Sensing ultraviolet light emission from hydrogen flames: Flame detection and flame monitoring in CO2 emission free domestic boilers

23. mai 2025 von sglux

Bielefeld, S.E., TU Delft Electrical Engineering, Mathematics and Computer Science


Master Thesis

Zusammenfassung
As a contribution to the decarbonisation of domestic heating, the graduation project investigates the feasibility of the application of UV sensor technology for flame detection and flame monitoring in hydrogen-powered domestic gas boilers. The research includes empirical studies and an analytical approach to describe influences on the sensor signal strength.
[_/su_spoiler]

Classé sous :Forschung, Veröffentlichungen und Berichte Balisé avec :flame, hydrogen, irradiance_lo, prod, stability

2017 – Degradation of opaque quartz-glass diffusers under high intensity UV irradiation

1. octobre 2017 von sglux

N. Papathanasiou, G. Hopfenmüller, Michael Matalla, T. Weiss,
sglux GmbH, Berlin, Germany

Presentation on IUVA World Congress Spotlights Water Disinfection Technologies 2017, Dubrovnik, Croatia

Abstract
In UV water purification applications UV sensors are monitoring the dosage of UV irradiation as according to ÖNORM and DVGW standards. sglux GmbH is manufacturing such sensors employing opaque synthetic quartz-glass diffusers as entrance windows. This paper investigates the influence of high-intensity UV irradiation on the transmission behavior of these diffusers. Quartz-glass and micro-porous quartz-glass were investigated. The sensors were continuously monitored while irradiated by a 1kW medium pressure Hg lamp with a total UV irradiance of 1000mW/cm² for 800 hours. Before and after the aging period the total transmissions of the diffusers were measured.

Classé sous :Forschung, Veröffentlichungen und Berichte Balisé avec :diffuser, irradiance_hi, science, sensors, stability

Adresse

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Germany
Tel: +49 (0) 30 53 01 52 11
Fax: +49 (0) 30 53 01 52 09
Mail:

sglux délivre partout dans le monde

Comme alternative, nous sommes représentés par nos partenaires de vente FARNELL et DISTRILEC, qui couvrent plus de 80 pays.

Dans votre région, la liste de spécialistes ci-dessous distribue nos produits et offrent leur assistance (presque) 24h/24 pour trouver la meilleure solution pour vos mesures UV:

Distributeurs
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Mentions légales Protection des données
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies