sglux-logo
bag-icon
Generic filters
Exact matches only
fr
  • Boutique
    • Photodiodes UV
    • TOCONs UV
      Photodiodes avec amplificateur de mesure intégré
    • Sondes de mesure UV
    • Radiomètres UV
    • Solutions personnalisées
    • Calibration UV
    • Mesure d’indice UV
    • Transducteurs de mesure pour photodiodes
  • Recherche
  • À propos
  • Contact
    • Distributeurs
    • Protection des données (en anglais)
    • Mentions légales
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Boutique
  • Recherche
  • À propos
  • Contact

2018 – UV Index measurements with SiC-based radiometers

11. juin 2018 von sglux

Johanna Luise Krueger², Dr. Niklas Papathanasiou¹, Stefan Langer¹, Gabriel Hopfenmueller¹, Dr. Tilman Weiss¹
¹sglux GmbH, Berlin, Germany, ²University of Freiberg, Germany

50th Annual Conference of the Radiation Protection Association 2018, Dresden, Germany

Abstract
Environmental data are collected to improve health-related quality of life of citizens. The solar UV-Index provides a good indicator for reasonable sun protection measures and duration of sun light exposure for safety officers and individuals. In Germany the “Bundesamt für Strahlenschutz” manages a solar UV-measurement network to monitor the UV-Index. At ten sites distributed all over Germany spectroradiometers are operated to measure the solar spectrum. The spectroradiometers are expensive and need highly qualified personnel to be operated. Robust and low-maintenance SiC-based UV-Index-radiometers are a viable option to increase the density of this measurement network at low cost. The spectral sensitivity function of such UV-Index-radiometers must reproduce the erythemal action function according to ISO 17166 with high precision.
In this contribution we investigate the effect of production tolerances in the spectral response of SiC-based UV-Index-radiometer (SiC-UVI-radiometer) onto the precision of the measured UV-Index. This is performed by folding a large number of different sun spectra with a variety of spectral responses of actual SiC-UVI-radiometer and the erythemal action curve as defined in the ISO 17166. We can show that the measurement uncertainty of SiC-based UVI-radiometers is ±5 % and therefore in the range of spectroradiometers. We simulated UVI measurements for SiC-based UVI-radiometers with over 2000 different sun spectra and determined a discrepancy-correction-function, which allows a precise UVI-measurement.

Classé sous :Recherche, Veröffentlichungen und Berichte

2018 – A new instrument for the hazard assessment of UV radiation

11. juin 2018 von sglux

Stefan Langer¹, Dr. Niklas Papathanasiou¹, Johanna Luise Krueger², Gabriel Hopfenmueller¹, Dr. Tilman Weiss¹
¹sglux GmbH, Berlin, Germany, ²University of Freiberg, Germany

50th Annual Conference of the Radiation Protection Association 2018, Dresden, Germany
Download article (noch nicht veröffentlicht)
Download poster

Abstract
Industrial application of ultraviolet radiation requires not only the evaluation of the effectiveness for the desired process but also an assessment of hazards for the operating personnel. Therefore rules and regulations have been established for the assessment and limitation of health-related threats. A variety of instruments are available on the market for this kind of risk assessment. These devices measure the radiation weighted according to applicable regulatory standards. But the final appraisal of risks such as maximum tolerable exposure time must still be computed manually afterwards.
The new approach presented here is based on a sensor with a spectral response characteristic tailored to a specific regulatory standard. This sensor is connected to a smart-phone. An application on the smart-phone will present the measurement value but also the maximum allowed exposure time in a graphical and acoustical manner. Each radiation source or regulatory guideline requires a specific sensor characteristic for an accurate risk assessment. Therefore the system extensively checks the requirements regarding the suitability of the connected sensor for the selected regulatory norm. These measures reduce the effort and the failure rate and also lower the burden for risk assessment in daily operation.

Classé sous :Recherche, Veröffentlichungen und Berichte

2018 – UV measurements for medical applications using SiC photodiodes

11. juin 2018 von sglux

Dr. Niklas Papathanasiou, Gabriel Hopfenmueller, Dr. Tilman Weiss
sglux GmbH, Berlin, Germany

Presentation on IoT-SNAP2018: IoT Enabling Sensing/Network/AI and Photonics Conference at
Optics & Photonics Intenational Congress OPIC 2018, Pacifico Yokohama, Yokohama, Japan

Abstract
In this contribution we report about SiC based UV photodiodes as the core component of smart UV sensors for various medical applications. In dialysis machines the transparency of urea is monitored by a SiC UV photodiode based UV transmission measurement module. A photodiode combined with an optical filter which reproduces the erythermal action spectrum helps Lupus patients to monitor their daily dose of solar UV radiation. sglux UVC sensor “UV-Safester” is a smartphone based tool to detect harmful UV radiation at a workplace employing the ICNIRP regulation. A wireless UV sensor module monitors the UV disinfection applied by disinfection robots in operating rooms.

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :general, irradiance_all, medical, sinter

2017 – Degradation of opaque quartz-glass diffusers under high intensity UV irradiation

11. juin 2017 von sglux

N. Papathanasiou, G. Hopfenmüller, Michael Matalla, T. Weiss,
sglux GmbH, Berlin, Germany

Presentation on IUVA World Congress Spotlights Water Disinfection Technologies 2017, Dubrovnik, Croatia

Abstract
In UV water purification applications UV sensors are monitoring the dosage of UV irradiation as according to ÖNORM and DVGW standards. sglux GmbH is manufacturing such sensors employing opaque synthetic quartz-glass diffusers as entrance windows. This paper investigates the influence of high-intensity UV irradiation on the transmission behavior of these diffusers. Quartz-glass and micro-porous quartz-glass were investigated. The sensors were continuously monitored while irradiated by a 1kW medium pressure Hg lamp with a total UV irradiance of 1000mW/cm² for 800 hours. Before and after the aging period the total transmissions of the diffusers were measured.

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :diffuser, irradiance_hi, science, sensors, stability

2017 – UV Index monitoring in Europe

11. juin 2017 von sglux

Alois W. Schmalwieser¹, Julian Gröbner², Mario Blumthaler³, Barbara Klotz³, Hugo De Backer⁴, David Bolsée⁵, Rolf Werner⁶, Davor Tomsic⁷, Ladislav Metelka⁸, Paul Eriksen⁹, Nis Jepsen⁹, Margit Aun¹⁰, Anu Heikkilä¹¹, Thierry Duprat¹², Henner Sandmann¹³, Tilman Weiss¹⁴, Alkis Bais¹⁵, Zoltan Toth¹⁶, Anna-Maria Siani¹⁷, Luisa Vaccaro¹⁸, Henri Diémoz¹⁹, Daniele Grifoni²⁰, Gaetano Zipoli²¹, Giuseppe Lorenzetto²², Boyan H. Petkov²³, Alcide Giorgio di Sarra²⁴, Francis Massen²⁵, Charles Yousif²⁶, Alexandr A. Aculinin²⁷, Peter den Outer²⁸, Tove Svendby²⁹, Arne Dahlback³⁰, Bjørn Johnsen³¹, Julita Biszczuk-Jakubowska³², Janusz Krzyscin³³, Diamantino Henriques³⁴, Natalia Chubarova³⁵, Predrag Kolarž³⁶, Zoran Mijatovic³⁷, Drago Groselj³⁸, Anna Pribullova³⁹, Juan Ramon Moreta Gonzales⁴⁰, Julia Bilbao⁴¹, José Manuel Vilaplana Guerrero⁴², Antonio Serrano⁴³, Sandra Andersson⁴⁴, Laurent Vuilleumier⁴⁵, Ann Webb⁴⁶, and John O’Hagan⁴⁷,

¹University of Veterinary Medicine, Unit of Physiology and Biophysics, Vienna, Austria, ²PMOD/WRC, Davos Dorf, Switzerland, ³Medical Univ. Innsbruck, Innsbruck, Austria, ⁴Royal Meteorological Institute of Belgium, Observations, Brussels, Belgium, ⁵Royal Belgian Institute for Space Aeronomy, Brussels, Belgium, ⁶Bulgarian Academy of Sciences, Stara Zagora, Bulgaria, ⁷Metorological and hydrological institute of Croatia, Metorological and hydrological institute of Croati, Croatia, ⁸Czech Hydrometeorological Institute, Solar and Ozone Department, Hradec Kralove, Czech Republic, ⁹Danish Meteorological Institute, Copenhagen, Denmark, ¹⁰Tartu Observatory, Tartumaa, Estonia, ¹¹Finnish Meteorological Institute, Helsinki, Finland, ¹²Météo-France, Toulouse Cedex, France, ¹³Bundesamt fur Strahlenschutz Neuherberg, Section for Optical Radiation, Neuherberg, Germany, ¹⁴sglux GmbH, Berlin, Germany, ¹⁵Aristotle University of Thessaloniki, Greece, ¹⁶Hungarian Meteorological Service, Marczell György Main Observatory, Budapest, Hungary, ¹⁷Sapienza Universita’ di Roma, Physics Department, Rome, Italy, ¹⁸ISPRA, Physical Agents Unit, Rome, Italy, ¹⁹ARPA Valle d’Aosta loc, Saint-Christophe, Italy, ²⁰LaMMA Consortium, Institute of Biometeorology of the National Research Council, Sesto Fiorentino, Italy, ²¹CNR-IBIMET, Florence, Italy, ²²ARPA di Vicenza, Vicenza, Italy, ²³National Research Council, Institute of Atmospheric Sciences and Climate, Bologna, Italy, ²⁴ENEA, Laboratory for Observations and Analyses of the Earth and Climate, Rome, Italy, ²⁵Lycée Classique de Diekirch, Computarium and meteoLCD, Diekirch, Luxembourg, ²⁶University of Malta, Institute for Sustainable Energy, Marsaxlokk, Malta, ²⁷Institute of Applied Physics of the Academy of Sciences of Moldova, Kishinev, Moldova (the Republic of), ²⁸Dutch National Health Institute (RIVM), Netherlands, ²⁹NILU – Norwegian Institute for Air Research, Kjeller, Norway, ³⁰University of Oslo, Institute of Physics, Oslo, Norway, ³¹Statens Stralevern, Monitoring and Research, Oesteras, Norway, ³²Institute of Meteorology and Water Management, Gdynia, Poland, ³³Institute of Geophysics, Polish Academy of Sciences, Warszw, Poland, ³⁴Instituto Português do Mar e da Atmosfera, Observatório Afonso Chaves, Ponta Delgada S. Miguel, Portugal, ³⁵Moscow State University, Moscow, Russian Federation, ³⁶University of Belgrade, Zemun, Serbia, ³⁷University of Novi Sad, Novi Sad, Serbia, ³⁸Slovenian Environment Agency, Ljubljana, Slovenia, ³⁹Slovakian Academy of Sciences, Tatranska Lomnica, Slovakia, ⁴⁰Spanish Meteorological Agency, Area of Atmospheric Observation Networks, Madrid, Spain, ⁴¹University of Valladolid, Valladolid, Spain, ⁴²National Institute for Aerospace Technology, Mazagon, Spain, ⁴³University of Extremadura, Department of Physics, Badajoz, Spain, ⁴⁴SMHI, Norköpping, Sweden, ⁴⁵MeteoSwiss, Atmospheric data division, Payerne, Switzerland, ⁴⁶University of Manchester, Manchester, United Kingdom of Great Britain and Northern Ireland, ⁴⁷Public Health England Centre for Radiation Chemical and Environmental Hazards, Radiation Dosimetry, Didcot, United Kingdom of Great Britain and Northern Ireland

Journal: Photochemical & Photobiological Sciences, Publisher: The Royal Society of Chemistry.

Abstract
The UV Index was established more than 20 years ago as a tool for sun protection and health care. Shortly after its introduction, UV Index monitoring started in several countries either by newly acquired instruments or by converting measurements from existing instruments into the UV Index. The number of stations and networks has increased over the years. Currently, 160 stations in 25 European countries deliver online values to the public via the Internet. In this paper an overview of these UV Index monitoring sites in Europe is given. The overview includes instruments as well as quality assurance and quality control procedures. Furthermore, some examples are given about how UV Index values are presented to the public. Through these efforts, 57% of the European population is supplied with high quality information, enabling them to adapt behaviour. Although health care, including skin cancer prevention, is cost-effective, a proportion of the European population still doesn’t have access to UV Index information.

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :general, irradiance_med, UVI

2014 – Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection

11. juin 2014 von sglux

P. Sperfeld¹, B. Barton¹, S. Pape¹, A. Towara¹, J. Eggers², G. Hopfenmueller³,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), Germany, ²DVGW-Technologiezentrum Wasser, Karlsruhe, Germany, ³sglux GmbH, Berlin, Germany

Metrologia, 51 (2014), S. 282-288.

Abstract
In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected low-pressure mercury and medium-pressure mercury UV lamps. To verify the calibration method and to perform on-site tests, spectral measurements were carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.

Classé sous :Recherche, Veröffentlichungen und Berichte

2014 – Spectral Irradiance Measurement and Actinic Radiometer Calibration for UV Water Disinfection

11. juin 2014 von sglux

P. Sperfeld¹, B. Barton¹, S. Pape¹, A. Towara¹, J. Eggers², G. Hopfenmueller³,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), Germany, ²DVGW-Technologiezentrum Wasser, Karlsruhe, Germany, ³sglux GmbH, Berlin, Germany

Proceedings of NEWRAD 2014, edited by S. Park, P. Kaerhae and E. Ikonen. (Aalto University, Espoo, Finland 2014) p. 128.

Abstract
In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected Hg low-pressure and medium-pressure UV radiators. To verify the calibration and to perform on-site tests, spectral measurements have been carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :irradiance_hi, önorm, science, water

2013 – PTB traceable calibrated reference UV radiometer for measurements at high irradiance medium pressure mercury discharge lamps

11. juin 2013 von sglux

G. Hopfenmueller¹, T.Weiss¹, B. Barton², P. Sperfeld², S. Nowy², S. Pape², D. Friedrich², S. Winter², A. Towara², A. Hoepe², S. Teichert²,
¹sglux GmbH, Berlin, Germany, ²Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :calibration, irradiance_hi, önorm, science

2013 – Traceable spectral irradiance measurements at UV water disinfection plants

11. juin 2013 von sglux

P. Sperfeld¹, B. Barton¹, S. Pape¹, G. Hopfenmueller²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Abstract
PTB provides spectral irradiance calibrations traceable to national primary standards and the SI system. Transportable spectroradiometer systems have been adapted for high UV irradiance measurements. Successful measurements at medium pressure Hg and low pressure Hg lamp facilities have been carried out. The effective microbicidal irradiances agree within 15%. 40° sensor geometry could be developed. Discussion about calibration service and support.

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :calibration, irradiance_hi, önorm, science

2013 – Developing and setting up a calibration facility for UV sensors at high irradiance rates

11. juin 2013 von sglux

B. Barton¹, P. Sperfeld¹, A. Towara¹, G. Hopfenmueller²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Abstract
PTB provides spectral irradiance calibrations traceable to national primary standards and the SI system. A transfer standard source for high UV irradiances has been constructed and characterized. A medium pressure Hg lamp and a low pressure Hg lamp provide different spectra at different irradiance levels. The system might serve as a calibration facility for DVGW & ÖNORM conform UV sensors. Calibration by direct substitution to reference sensors can be carried out.

Classé sous :Recherche, Veröffentlichungen und Berichte Balisé avec :calibration, irradiance_hi, önorm, science

  • « Page précédente
  • 1
  • 2
  • 3
  • 4
  • Page suivante »

Adresse

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Germany
Tel: +49 (0) 30 53 01 52 11
Fax: +49 (0) 30 53 01 52 09
Mail:

sglux délivre partout dans le monde

Comme alternative, nous sommes représentés par nos partenaires de vente FARNELL et DISTRILEC, qui couvrent plus de 80 pays.

Dans votre région, la liste de spécialistes ci-dessous distribue nos produits et offrent leur assistance (presque) 24h/24 pour trouver la meilleure solution pour vos mesures UV:

Distributeurs
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Mentions légales Protection des données
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies