sglux-logo
bag-icon
Generic filters
Exact matches only
es
  • Tienda
    • Fotodiodos UV
    • TOCONs UV
      Fotodiodos con amplificador de medida integrado
    • Sondas de medición UV
    • Radiómetros UV
    • Soluciones personalizadas
    • Calibración UV
    • Medición del Índice UV
    • Transductores de medida para fotodiodos
  • Investigación
  • Sobre nosotros
  • Contacto
    • Distribuidores
    • Politica de privacidad
    • Aviso legal
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Tienda
  • Investigación
  • Sobre nosotros
  • Contacto

2023 – Towards Sic-Based VUV Pin-Photodiodes – Investigations on 4H-SiC Photodiodes with Shallow Implanted Al Emitters

23. mayo 2025 von sglux

Michael Schraml¹, Alexander May¹, Dr. Tobias Erlbacher¹, Dr. Niklas Papathanasiou², Dr. Tilman Weiss²,
¹Fraunhofer IISB, Erlangen, Germany
²sglux GmbH, Berlin, Germany

Towards SiC-Based VUV Pin-Photodiodes – Investigations on 4H-SiC Photodiodes with Shallow Implanted Al Emitters

Zusammenfassung
4H silicon carbide (SiC) based pin photodiodes with a sensitivity in the vacuum ultraviolet spectrum (VUV) demand newly developed emitter doping profiles. This work features the first ever reported 4H-SiC pin photodiodes with an implanted p-emitter and a noticeable sensitivity at a wavelength of 200 nm. As a first step, Aluminum doping profiles produced by low energy ion implantation in 4H-SiC were characterized by secondary-ion mass spectrometry (SIMS). Photodiodes using these shallow emitters are compared to one with a deep p-emitter doping profile employing IV characteristics and the spectral response. SIMS results demonstrate the possibility of shallow Alimplantation profiles using low implantation energies with all emitter profiles featuring characteristic I-V results. For some shallow doping profiles, a meassurable signal at the upper limit of the VUV spectrum could be demonstrated, paving the way towards 4H-SiC pin photodiodes with sensitivities for wavelengths below 200 nm.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: flame, irradiance_all, science, VUV

2024 Digitale Sonden als UV-Radiometer – Das Smartphone wird zum Messgerät

12. diciembre 2024 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

Zusammenfassung

Sensor Magazin 4/2024 (c) Magazin Verlag

UV-Strahlung wird in vielen Bereichen der industriellen Fertigung, in medizintechnischen Geräten und zur Desinfektion eingesetzt. Die präzise Messung der Bestrahlungsstärke ist für eine kontrollierte und effiziente Nutzung der UV-Strahlung wichtig. Die für diese Anwendungen eingesetzten UV-Messgeräte müssen in der Lage sein die UV-Bestrahlungsstärke über 13 Größenordnungen hinweg, von wenigen pW/cm² bis zu 10 W/cm² zuverlässig, reproduzierbar und rückführbar zu messen. Hier spielen Digitale Mess-Sonden ihre Stärken aus.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: irradiance_all, prod, radiometer, sxl55

2024 – Digital UV Sensors simplify measurement and control

23. julio 2024 von sglux

Dr. Tilman Weiss¹, Fred Perry²
¹sglux GmbH, Berlin, Germany
²Boston Electronics Corporation, Brookline, USA

Journal Contribution to the IUVA UV Solutions Magazine (c) IUVA

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: digiprobe, irradiance_all, prod, radiometer, sensors

2024 – UV-Strahlung messen ohne Filter – Siliziumcarbid (SiC) – Photodioden machen’s möglich

1. febrero 2024 von sglux

Dr. Niklas Papathanasiou, sglux GmbH, Berlin, Germany

Sensor Magazin 2/2024 (c) Magazin Verlag

Zusammenfassung
Das Berliner Unternehmen sglux GmbH produziert seit mehr als 20 Jahren Photodioden und Sensoren zur Messung von UV-Strahlung, wie sie in vielen Bereichen der industriellen Fertigung, der Medizintechnik, der Feuerungstechnik und zur Entkeimungsüberwachung zum Einsatz kommen. Die präzise Erfassung der ultravioletten Bestrahlungsstärke ist für eine kontrollierte und effiziente Funktionsweise von hoher Bedeutung. sglux löst diese Aufgaben mit SiC-basierten Photodioden, seit 2009 aus eigener Halbleiterproduktion. Bei der Detektion von UV-Strahlung sind SiC-Photodioden aufgrund ihrer hohen Bandlücke von 3.26 eV im Vorteil, da sie gegenüber sichtbarer und nah-infraroter Strahlung blind sind. Zudem weisen SiC-Photodioden sehr niedrige Dunkelströme auf, sodass auch kleinste Strahlungsmengen nachgewiesen werden können. Im Bereich der Messung starker UV-Strahlung punktet SiC mit seiner hohen Degradationsfestigkeit.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: general, irradiance_all, photodiodes, sensors

2023 – Approaches of LED in-line measurements and its traceable calibration

18. septiembre 2023 von sglux

Gabriel Hopfenmüller, Dr. Niklas Papathanasiou, sglux GmbH, Berlin, Germany

InterAqua Japan 01. – 03.02.2023
Approaches of LED in-line measurements and its traceable calibration

Zusammenfassung
UV measurement at UV LED arrays.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: calibration, irradiance_all, led, prod, VUV

2023 – 4H-SiC PIN Photodiode for VUV Detection Using an Enhanced Emitter Doping Design

3. julio 2023 von sglux

M. Schraml¹, N. Papathanasiou², A. May¹, M. Rommel¹, T. Erlbacher³
¹Fraunhofer IISB, Erlangen, Germany
²sglux GmbH, Berlin, Germany
³Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany

2023 IEEE Photonics Conference (IPC) 12. – 16.11.2023
4H-SiC PIN Photodiode for VUV Detection Using an Enhanced Emitter Doping Desig

Zusammenfassung
The fabrication of a novel Vacuum UV (VUV) sensitive 4H-SiC pin photodiode is presented. Aluminum ion implantation was used to fabricate a patterned emitter structure with p – and p + regions resulting in the highest reported VUV sensitivity for a SiC pin photodiode.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: irradiance_all, photodiodes, science, VUV

2022 – How to determine the right UV sensor for flame detection?

19. septiembre 2022 von sglux

Dr. Tilman Weiss, sglux GmbH, Berlin, Germany

How to determine the right UV sensor for flame detection?

Zusammenfassung
The present article informs about different approaches using UV photodetectors for the detection of a combustion flame (natural gas, hydrogen or oil).

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: customized, flame, general, irradiance_all

2022 – Marker Substances in the Aroma of Truffles

5. abril 2022 von sglux

Ruben Epping¹, Lilly Bliesener¹, Dr. Tilman Weiss², Matthias Koch¹, *
¹Division of Organic Trace Analysis and Food Analysis, Bundesanstalt für Materialforschung und -Prüfung, Berlin, Germany
²sglux GmbH, Berlin, Germany
*Authors to whom correspondence should be addressed.

Marker Substances in the Aroma of Truffles

Zusammenfassung
The aim of this study was to identify specific truffle marker substances within the truffle aroma. The aroma profile of different truffle species was analyzed using static headspace sampling with gas chromatography mass spectrometry analysis (SHS/GC-MS). Possible marker substances were identified, taking the additional literature into account. The selected marker substances were tested in an experiment with 19 truffle dogs. The hypothesis “If trained truffle dogs recognize the substances as supposed truffles in the context of an experiment, they can be regarded as specific” was made. As it would be nearly impossible to investigate every other possible emitter of the same compounds to determine their specificity, this hypothesis was a reasonable approximation. We were interested in the question of what it is the dogs actually search for on a chemical level and whether we can link their ability to find truffles to one or more specific marker substances. The results of the dog experiment are not as unambiguous as could have been expected based on the SHS/GC-MS measurements. Presumably, the truffle aroma is mainly characterized and perceived by dogs by dimethyl sulfide and dimethyl disulfide. However, as dogs are living beings and not analytical instruments, it seems unavoidable that one must live with some degree of uncertainty regarding these results.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: customized, fluorescence, gap, irradiance_lo, science, truffles

2021 – How two sglux photodiodes contribute to the NASA 2021 Perseverance mission

30. noviembre 2021 von sglux

Luther W. Beegle et al.
Space Sci Rev (2021) 217:58

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

Zusammenfassung
The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Labora- tory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are natu- rally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Aut- ofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spa- tial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7×7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which sam- ples to collect and cache for Mars sample return.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: irradiance_all, photodiodes, science, UVI

2021 – Sensing ultraviolet light emission from hydrogen flames: Flame detection and flame monitoring in CO2 emission free domestic boilers

1. agosto 2021 von sglux

Bielefeld, S.E., TU Delft Electrical Engineering, Mathematics and Computer Science


Master Thesis

Zusammenfassung
As a contribution to the decarbonisation of domestic heating, the graduation project investigates the feasibility of the application of UV sensor technology for flame detection and flame monitoring in hydrogen-powered domestic gas boilers. The research includes empirical studies and an analytical approach to describe influences on the sensor signal strength.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: flame, hydrogen, irradiance_lo, prod, stability

  • « Página anterior
  • 1
  • 2
  • 3
  • 4
  • Página siguiente »

Dirección

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Alemania
Tel: +49 (0) 30 53 01 52 11
Fax: +49 (0) 30 53 01 52 09
Mail:

sglux suministra en todo el mundo

Como alternativa, somos representados a través de nuestros distribuidores mundiales FARNELL y GERHARD en más de 80 países.

En su región, los siguientes especialistas distribuyen nuestros productos y proporcionan asesoramiento profesional para encontrar la mejor solución en su trabajo de medición UV (casi) todo el día:

Distribuidores
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Aviso legal Politica de privacidad LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies