sglux-logo
bag-icon
Generic filters
Exact matches only
es
  • Tienda
    • Fotodiodos UV
    • TOCONs UV
      Fotodiodos con amplificador de medida integrado
    • Sondas de medición UV
    • Radiómetros UV
    • Soluciones personalizadas
    • Calibración UV
    • Medición del Índice UV
    • Transductores de medida para fotodiodos
  • Investigación
  • Sobre nosotros
  • Contacto
    • Distribuidores
    • Politica de privacidad
    • Aviso legal
  • DE
  • EN
  • ES
  • FR

sglux

UV is our Business

  • DE
  • EN
  • ES
  • FR
Generic filters
Exact matches only
  • Tienda
  • Investigación
  • Sobre nosotros
  • Contacto

2018 – UV measurements for medical applications using SiC photodiodes

14. septiembre 2018 von sglux

Dr. Niklas Papathanasiou, Gabriel Hopfenmueller, Dr. Tilman Weiss
sglux GmbH, Berlin, Germany

Presentation on IoT-SNAP2018: IoT Enabling Sensing/Network/AI and Photonics Conference at
Optics & Photonics Intenational Congress OPIC 2018, Pacifico Yokohama, Yokohama, Japan

Abstract
In this contribution we report about SiC based UV photodiodes as the core component of smart UV sensors for various medical applications. In dialysis machines the transparency of urea is monitored by a SiC UV photodiode based UV transmission measurement module. A photodiode combined with an optical filter which reproduces the erythermal action spectrum helps Lupus patients to monitor their daily dose of solar UV radiation. sglux UVC sensor “UV-Safester” is a smartphone based tool to detect harmful UV radiation at a workplace employing the ICNIRP regulation. A wireless UV sensor module monitors the UV disinfection applied by disinfection robots in operating rooms.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: general, irradiance_all, medical, sinter

2017 – UV Index monitoring in Europe

10. octubre 2017 von sglux

Alois W. Schmalwieser¹, Julian Gröbner², Mario Blumthaler³, Barbara Klotz³, Hugo De Backer⁴, David Bolsée⁵, Rolf Werner⁶, Davor Tomsic⁷, Ladislav Metelka⁸, Paul Eriksen⁹, Nis Jepsen⁹, Margit Aun¹⁰, Anu Heikkilä¹¹, Thierry Duprat¹², Henner Sandmann¹³, Tilman Weiss¹⁴, Alkis Bais¹⁵, Zoltan Toth¹⁶, Anna-Maria Siani¹⁷, Luisa Vaccaro¹⁸, Henri Diémoz¹⁹, Daniele Grifoni²⁰, Gaetano Zipoli²¹, Giuseppe Lorenzetto²², Boyan H. Petkov²³, Alcide Giorgio di Sarra²⁴, Francis Massen²⁵, Charles Yousif²⁶, Alexandr A. Aculinin²⁷, Peter den Outer²⁸, Tove Svendby²⁹, Arne Dahlback³⁰, Bjørn Johnsen³¹, Julita Biszczuk-Jakubowska³², Janusz Krzyscin³³, Diamantino Henriques³⁴, Natalia Chubarova³⁵, Predrag Kolarž³⁶, Zoran Mijatovic³⁷, Drago Groselj³⁸, Anna Pribullova³⁹, Juan Ramon Moreta Gonzales⁴⁰, Julia Bilbao⁴¹, José Manuel Vilaplana Guerrero⁴², Antonio Serrano⁴³, Sandra Andersson⁴⁴, Laurent Vuilleumier⁴⁵, Ann Webb⁴⁶, and John O’Hagan⁴⁷,

¹University of Veterinary Medicine, Unit of Physiology and Biophysics, Vienna, Austria, ²PMOD/WRC, Davos Dorf, Switzerland, ³Medical Univ. Innsbruck, Innsbruck, Austria, ⁴Royal Meteorological Institute of Belgium, Observations, Brussels, Belgium, ⁵Royal Belgian Institute for Space Aeronomy, Brussels, Belgium, ⁶Bulgarian Academy of Sciences, Stara Zagora, Bulgaria, ⁷Metorological and hydrological institute of Croatia, Metorological and hydrological institute of Croati, Croatia, ⁸Czech Hydrometeorological Institute, Solar and Ozone Department, Hradec Kralove, Czech Republic, ⁹Danish Meteorological Institute, Copenhagen, Denmark, ¹⁰Tartu Observatory, Tartumaa, Estonia, ¹¹Finnish Meteorological Institute, Helsinki, Finland, ¹²Météo-France, Toulouse Cedex, France, ¹³Bundesamt fur Strahlenschutz Neuherberg, Section for Optical Radiation, Neuherberg, Germany, ¹⁴sglux GmbH, Berlin, Germany, ¹⁵Aristotle University of Thessaloniki, Greece, ¹⁶Hungarian Meteorological Service, Marczell György Main Observatory, Budapest, Hungary, ¹⁷Sapienza Universita’ di Roma, Physics Department, Rome, Italy, ¹⁸ISPRA, Physical Agents Unit, Rome, Italy, ¹⁹ARPA Valle d’Aosta loc, Saint-Christophe, Italy, ²⁰LaMMA Consortium, Institute of Biometeorology of the National Research Council, Sesto Fiorentino, Italy, ²¹CNR-IBIMET, Florence, Italy, ²²ARPA di Vicenza, Vicenza, Italy, ²³National Research Council, Institute of Atmospheric Sciences and Climate, Bologna, Italy, ²⁴ENEA, Laboratory for Observations and Analyses of the Earth and Climate, Rome, Italy, ²⁵Lycée Classique de Diekirch, Computarium and meteoLCD, Diekirch, Luxembourg, ²⁶University of Malta, Institute for Sustainable Energy, Marsaxlokk, Malta, ²⁷Institute of Applied Physics of the Academy of Sciences of Moldova, Kishinev, Moldova (the Republic of), ²⁸Dutch National Health Institute (RIVM), Netherlands, ²⁹NILU – Norwegian Institute for Air Research, Kjeller, Norway, ³⁰University of Oslo, Institute of Physics, Oslo, Norway, ³¹Statens Stralevern, Monitoring and Research, Oesteras, Norway, ³²Institute of Meteorology and Water Management, Gdynia, Poland, ³³Institute of Geophysics, Polish Academy of Sciences, Warszw, Poland, ³⁴Instituto Português do Mar e da Atmosfera, Observatório Afonso Chaves, Ponta Delgada S. Miguel, Portugal, ³⁵Moscow State University, Moscow, Russian Federation, ³⁶University of Belgrade, Zemun, Serbia, ³⁷University of Novi Sad, Novi Sad, Serbia, ³⁸Slovenian Environment Agency, Ljubljana, Slovenia, ³⁹Slovakian Academy of Sciences, Tatranska Lomnica, Slovakia, ⁴⁰Spanish Meteorological Agency, Area of Atmospheric Observation Networks, Madrid, Spain, ⁴¹University of Valladolid, Valladolid, Spain, ⁴²National Institute for Aerospace Technology, Mazagon, Spain, ⁴³University of Extremadura, Department of Physics, Badajoz, Spain, ⁴⁴SMHI, Norköpping, Sweden, ⁴⁵MeteoSwiss, Atmospheric data division, Payerne, Switzerland, ⁴⁶University of Manchester, Manchester, United Kingdom of Great Britain and Northern Ireland, ⁴⁷Public Health England Centre for Radiation Chemical and Environmental Hazards, Radiation Dosimetry, Didcot, United Kingdom of Great Britain and Northern Ireland

Journal: Photochemical & Photobiological Sciences, Publisher: The Royal Society of Chemistry.

Abstract
The UV Index was established more than 20 years ago as a tool for sun protection and health care. Shortly after its introduction, UV Index monitoring started in several countries either by newly acquired instruments or by converting measurements from existing instruments into the UV Index. The number of stations and networks has increased over the years. Currently, 160 stations in 25 European countries deliver online values to the public via the Internet. In this paper an overview of these UV Index monitoring sites in Europe is given. The overview includes instruments as well as quality assurance and quality control procedures. Furthermore, some examples are given about how UV Index values are presented to the public. Through these efforts, 57% of the European population is supplied with high quality information, enabling them to adapt behaviour. Although health care, including skin cancer prevention, is cost-effective, a proportion of the European population still doesn’t have access to UV Index information.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: general, irradiance_med, UVI

2017 – Degradation of opaque quartz-glass diffusers under high intensity UV irradiation

1. octubre 2017 von sglux

N. Papathanasiou, G. Hopfenmüller, Michael Matalla, T. Weiss,
sglux GmbH, Berlin, Germany

Presentation on IUVA World Congress Spotlights Water Disinfection Technologies 2017, Dubrovnik, Croatia

Abstract
In UV water purification applications UV sensors are monitoring the dosage of UV irradiation as according to ÖNORM and DVGW standards. sglux GmbH is manufacturing such sensors employing opaque synthetic quartz-glass diffusers as entrance windows. This paper investigates the influence of high-intensity UV irradiation on the transmission behavior of these diffusers. Quartz-glass and micro-porous quartz-glass were investigated. The sensors were continuously monitored while irradiated by a 1kW medium pressure Hg lamp with a total UV irradiance of 1000mW/cm² for 800 hours. Before and after the aging period the total transmissions of the diffusers were measured.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: diffuser, irradiance_hi, science, sensors, stability

2014 – Spectral Irradiance Measurement and Actinic Radiometer Calibration for UV Water Disinfection

23. noviembre 2014 von sglux

P. Sperfeld¹, B. Barton¹, S. Pape¹, A. Towara¹, J. Eggers², G. Hopfenmueller³,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), Germany, ²DVGW-Technologiezentrum Wasser, Karlsruhe, Germany, ³sglux GmbH, Berlin, Germany

Proceedings of NEWRAD 2014, edited by S. Park, P. Kaerhae and E. Ikonen. (Aalto University, Espoo, Finland 2014) p. 128.

Abstract
In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected Hg low-pressure and medium-pressure UV radiators. To verify the calibration and to perform on-site tests, spectral measurements have been carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: irradiance_hi, önorm, science, water

2013 – Developing and setting up a calibration facility for UV sensors at high irradiance rates

7. octubre 2013 von sglux

B. Barton¹, P. Sperfeld¹, A. Towara¹, G. Hopfenmueller²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Abstract
PTB provides spectral irradiance calibrations traceable to national primary standards and the SI system. A transfer standard source for high UV irradiances has been constructed and characterized. A medium pressure Hg lamp and a low pressure Hg lamp provide different spectra at different irradiance levels. The system might serve as a calibration facility for DVGW & ÖNORM conform UV sensors. Calibration by direct substitution to reference sensors can be carried out.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: calibration, irradiance_hi, önorm, science

2013 – PTB traceable calibrated reference UV radiometer for measurements at high irradiance medium pressure mercury discharge lamps

7. julio 2013 von sglux

G. Hopfenmueller¹, T.Weiss¹, B. Barton², P. Sperfeld², S. Nowy², S. Pape², D. Friedrich², S. Winter², A. Towara², A. Hoepe², S. Teichert²,
¹sglux GmbH, Berlin, Germany, ²Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: calibration, irradiance_hi, önorm, science

2013 – Traceable spectral irradiance measurements at UV water disinfection plants

21. marzo 2013 von sglux

P. Sperfeld¹, B. Barton¹, S. Pape¹, G. Hopfenmueller²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

EMEA Regional Conference, Karlsruhe, Germany (2013)

Abstract
PTB provides spectral irradiance calibrations traceable to national primary standards and the SI system. Transportable spectroradiometer systems have been adapted for high UV irradiance measurements. Successful measurements at medium pressure Hg and low pressure Hg lamp facilities have been carried out. The effective microbicidal irradiances agree within 15%. 40° sensor geometry could be developed. Discussion about calibration service and support.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: calibration, irradiance_hi, önorm, science

2012 – Highly reliable Silicon Carbide photodiodes for visible-blind ultraviolet detector applications

30. julio 2012 von sglux

D. Prasai¹, W. John¹, L. Weixelbaum¹, O. Krueger¹, G. Wagner², P. Sperfeld³, S. Nowy³, D. Friedrich³, S. Winter³ and T. Weiss⁴,
¹Ferdinand-Braun-Institut, Leibniz-Institut fuer Hoechstfrequenztechnik, Berlin, Germany, ²Leibniz-Institut fuer Kristallzuechtung, Berlin, Germany, ³Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ⁴sglux GmbH, Berlin, Germany

J. Mater. Res., first view (2012).

Abstract
Highly efficient polytype 4H silicon carbide (4H-SiC) p–n diodes for ultraviolet (UV) light detection have been fabricated, characterized, and exposed to high-intensity mercury lamp irradiation (up to 17 mW/cm²). The behavior of the photocurrent response under UV light irradiation using a low-pressure mercury UV-C lamp (4 mW/cm²) and a medium-pressure mercury discharge lamp (17 mW/cm²) has been studied. We report on long-term UV photoaging tests performed for up to 22 mo. Results demonstrate the robustness of SiC photodiodes against UV radiation. The devices under test showed an initial burn-in effect, i.e., the photocurrent response dropped by less than 5% within the first 40 h of artificial UV aging. Such burn-in effect under UV stress was also observed for previously available polytype 6H silicon carbide (6H–SiC) p–n photodetectors. After burn-in, no measurable degradation has been detected, which makes the devices excellent candidates for high irradiance UV detector applications.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: calibration, irradiance_all, photodiodes, prod

2011 – Characterisation of new optical diffusers used in high irradiance UV radiometers

23. noviembre 2011 von sglux

Barton¹, B., Sperfeld¹, P., Nowy¹, S., Towara¹, A., Hoepe¹, A., Teichert¹, S., Hopfenmueller², G., Baer³, M. and Kreuzberger³, T.
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany, ³SGIL Silicaglas GmbH, Langewiesen, Germany

Proceedings of NEWRAD2011, edited by S. Park and E. Ikonen. (Aalto University, Espoo, Finland, 2011) p. 278.

Abstract
Diffusers are essential components of UV radiometers used as transfer standards. They improve the insensitivity to differing radiation situations. In combination with a beam limiting aperture, a diffuser defines the irradiated area [1]. A detailed study of different properties of UV diffusers is shown.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: curing, diffuser, irradiance_hi, science, sensors

2011 – Characterisation of SiC photodiodes for high irradiance UV radiometers

23. noviembre 2011 von sglux

S. Nowy¹, B. Barton¹, S. Pape¹, P. Sperfeld¹, D. Friedrich¹, S. Winter¹, G. Hopfenmueller², and T. Weiss²,
¹Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (PTB), 4.1 Photometry and Applied Radiometry, Braunschweig, Germany, ²sglux GmbH, Berlin, Germany

Proceedings of NEWRAD2011, edited by S. Park and E. Ikonen. (Aalto University, Espoo, Finland, 2011) p. 203.

Abstract
For monitoring high UV irradiance, silicon carbide (SiC) based photodiodes are used. In this paper we describe the characterization of the novel SiC UV photodiodes in terms of their spectral and integral responsivity. Special attention is paid to the aging behavior of the photodiodes due to high UV irradiance. Artificial aging of the samples is performed by illumination with a high power medium pressure mercury discharge lamp.

Publicado en: Forschung, Veröffentlichungen und Berichte Etiquetado como: irradiance_hi, photodiodes, science

  • « Página anterior
  • 1
  • …
  • 3
  • 4
  • 5

Dirección

sglux GmbH
Richard-Willstätter-Str. 8
12489 Berlin, Alemania
Tel: +49 (0) 30 53 01 52 11
Fax: +49 (0) 30 53 01 52 09
Mail:

sglux suministra en todo el mundo

Como alternativa, somos representados a través de nuestros distribuidores mundiales FARNELL y GERHARD en más de 80 países.

En su región, los siguientes especialistas distribuyen nuestros productos y proporcionan asesoramiento profesional para encontrar la mejor solución en su trabajo de medición UV (casi) todo el día:

Distribuidores
sglux GmbH 2024
Richard-Willstätter-Str. 8
D-12489 Berlin
Tel: +49 (0) 30 53 01 52 11
Mail: welcome@sglux.de
Aviso legal Politica de privacidad LinkedIn
We do not use any cookies for tracking or analyzing of your website visit. However, technical cookies are needed to enable shop orders and to follow your language preferences.
Imprint | Privacy Policy
I accept cookies