{"id":10548,"date":"2025-06-05T07:57:40","date_gmt":"2025-06-05T05:57:40","guid":{"rendered":"https:\/\/sglux.de\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/"},"modified":"2025-06-10T15:45:40","modified_gmt":"2025-06-10T13:45:40","slug":"2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame","status":"publish","type":"post","link":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/","title":{"rendered":"2025 &#8211; Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame"},"content":{"rendered":"<p>Dr. Tilman Weiss, sglux GmbH, Berlin, Germany<br \/>\nYuyu Kimura, IR System Co., Ltd., Tokyo, Japan<\/p>\n<p style=\"text-align: left;\">This article was first published in the Japanese Journal of Industrial Heating 2025, vol. 62, no. 3, Edition May<br \/>\n<strong><a href=\"https:\/\/download.sglux.de\/publications\/sglux_flame_detection_solutions_hydrogen.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame<\/a><\/strong><\/p>\n<p align=\"justify\"><em>Abstrait<\/em><br \/>\nUsing semiconductor based sensors for flame detection, such as presented with this article can be regarded as a fascinating approach not just with regards on costs and safety. Additionally, looking at environmental and sustainability aspects using semiconductor sensors instead of discharge tubes is a useful tool towards durability and longevity. The possibility of working with two different sensor chips for two different kind of irradiadion (UV and IR) in one small size sensor housing opens up a multitude of new and interesting application possibilities.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dr. Tilman Weiss, sglux GmbH, Berlin, Germany <br \/>\nYuyu Kimura, IR System Co., Ltd., Tokyo, Japan<\/p>\n<p>This article was first published in the Japanese Journal of Industrial Heating 2025, vol. 62, no. 3, Edition May<\/p>\n<p style=\"text-align: center;\">\n<strong><a href=\"https:\/\/download.sglux.de\/publications\/sglux_flame_detection_solutions_hydrogen.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame<\/a><\/strong><\/p>\n<p><\/p>\n<p align=\"justify\"><em>Abstrait<\/em><br \/>\n<br \/>\nUsing semiconductor based sensors for flame detection, such as presented with this article can be regarded as a fascinating approach not just with regards on costs and safety. Additionally, looking at environmental and sustainability aspects using semiconductor sensors instead of discharge tubes is a useful tool towards durability and longevity. The possibility of working with two different sensor chips for two different kind of irradiadion (UV and IR) in one small size sensor housing opens up a multitude of new and interesting application possibilities.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[499],"tags":[371,401,402],"class_list":{"0":"post-10548","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-publications-fr","7":"tag-feuererkennung-fr","8":"tag-flame-fr","9":"tag-flame_detection-fr","10":"entry"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame | sglux<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame | sglux\" \/>\n<meta property=\"og:description\" content=\"Dr. Tilman Weiss, sglux GmbH, Berlin, Germany  Yuyu Kimura, IR System Co., Ltd., Tokyo, Japan  This article was first published in the Japanese Journal of Industrial Heating 2025, vol. 62, no. 3, Edition May    Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame   Abstrait  Using semiconductor based sensors for flame detection, such as presented with this article can be regarded as a fascinating approach not just with regards on costs and safety. Additionally, looking at environmental and sustainability aspects using semiconductor sensors instead of discharge tubes is a useful tool towards durability and longevity. The possibility of working with two different sensor chips for two different kind of irradiadion (UV and IR) in one small size sensor housing opens up a multitude of new and interesting application possibilities.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\" \/>\n<meta property=\"og:site_name\" content=\"sglux\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-05T05:57:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-10T13:45:40+00:00\" \/>\n<meta name=\"author\" content=\"sglux\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"sglux\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\"},\"author\":{\"name\":\"sglux\",\"@id\":\"https:\/\/sglux.de\/fr\/#\/schema\/person\/2b3b322bc60340429a282cd9253a76ad\"},\"headline\":\"2025 &#8211; Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame\",\"datePublished\":\"2025-06-05T05:57:40+00:00\",\"dateModified\":\"2025-06-10T13:45:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\"},\"wordCount\":141,\"publisher\":{\"@id\":\"https:\/\/sglux.de\/fr\/#organization\"},\"keywords\":[\"Feuererkennung\",\"flame\",\"flame_detection\"],\"articleSection\":[\"Ver\u00f6ffentlichungen und Berichte\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\",\"url\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\",\"name\":\"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame | sglux\",\"isPartOf\":{\"@id\":\"https:\/\/sglux.de\/fr\/#website\"},\"datePublished\":\"2025-06-05T05:57:40+00:00\",\"dateModified\":\"2025-06-10T13:45:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/sglux.de\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sglux.de\/fr\/#website\",\"url\":\"https:\/\/sglux.de\/fr\/\",\"name\":\"sglux\",\"description\":\"UV is our Business\",\"publisher\":{\"@id\":\"https:\/\/sglux.de\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sglux.de\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sglux.de\/fr\/#organization\",\"name\":\"sglux GmbH\",\"url\":\"https:\/\/sglux.de\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/sglux.de\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sglux.de\/data-matrix\/uploads\/2024\/11\/sglux_logo_uv_senesoren_gelb.png\",\"contentUrl\":\"https:\/\/sglux.de\/data-matrix\/uploads\/2024\/11\/sglux_logo_uv_senesoren_gelb.png\",\"width\":550,\"height\":116,\"caption\":\"sglux GmbH\"},\"image\":{\"@id\":\"https:\/\/sglux.de\/fr\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/sglux-gmbh\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/sglux.de\/fr\/#\/schema\/person\/2b3b322bc60340429a282cd9253a76ad\",\"name\":\"sglux\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame | sglux","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/","og_locale":"fr_FR","og_type":"article","og_title":"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame | sglux","og_description":"Dr. Tilman Weiss, sglux GmbH, Berlin, Germany  Yuyu Kimura, IR System Co., Ltd., Tokyo, Japan  This article was first published in the Japanese Journal of Industrial Heating 2025, vol. 62, no. 3, Edition May    Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame   Abstrait  Using semiconductor based sensors for flame detection, such as presented with this article can be regarded as a fascinating approach not just with regards on costs and safety. Additionally, looking at environmental and sustainability aspects using semiconductor sensors instead of discharge tubes is a useful tool towards durability and longevity. The possibility of working with two different sensor chips for two different kind of irradiadion (UV and IR) in one small size sensor housing opens up a multitude of new and interesting application possibilities.","og_url":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/","og_site_name":"sglux","article_published_time":"2025-06-05T05:57:40+00:00","article_modified_time":"2025-06-10T13:45:40+00:00","author":"sglux","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"sglux","Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/#article","isPartOf":{"@id":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/"},"author":{"name":"sglux","@id":"https:\/\/sglux.de\/fr\/#\/schema\/person\/2b3b322bc60340429a282cd9253a76ad"},"headline":"2025 &#8211; Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame","datePublished":"2025-06-05T05:57:40+00:00","dateModified":"2025-06-10T13:45:40+00:00","mainEntityOfPage":{"@id":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/"},"wordCount":141,"publisher":{"@id":"https:\/\/sglux.de\/fr\/#organization"},"keywords":["Feuererkennung","flame","flame_detection"],"articleSection":["Ver\u00f6ffentlichungen und Berichte"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/","url":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/","name":"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame | sglux","isPartOf":{"@id":"https:\/\/sglux.de\/fr\/#website"},"datePublished":"2025-06-05T05:57:40+00:00","dateModified":"2025-06-10T13:45:40+00:00","breadcrumb":{"@id":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sglux.de\/fr\/2025-flame-monitoring-in-industrial-burners-with-semiconductor-based-uv-sensors-focusing-on-hydrogen-flame\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/sglux.de\/fr\/"},{"@type":"ListItem","position":2,"name":"2025 - Flame monitoring in industrial burners with semiconductor-based UV sensors focusing on hydrogen-flame"}]},{"@type":"WebSite","@id":"https:\/\/sglux.de\/fr\/#website","url":"https:\/\/sglux.de\/fr\/","name":"sglux","description":"UV is our Business","publisher":{"@id":"https:\/\/sglux.de\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sglux.de\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/sglux.de\/fr\/#organization","name":"sglux GmbH","url":"https:\/\/sglux.de\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/sglux.de\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/sglux.de\/data-matrix\/uploads\/2024\/11\/sglux_logo_uv_senesoren_gelb.png","contentUrl":"https:\/\/sglux.de\/data-matrix\/uploads\/2024\/11\/sglux_logo_uv_senesoren_gelb.png","width":550,"height":116,"caption":"sglux GmbH"},"image":{"@id":"https:\/\/sglux.de\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sglux-gmbh"]},{"@type":"Person","@id":"https:\/\/sglux.de\/fr\/#\/schema\/person\/2b3b322bc60340429a282cd9253a76ad","name":"sglux"}]}},"_links":{"self":[{"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/posts\/10548","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/comments?post=10548"}],"version-history":[{"count":26,"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/posts\/10548\/revisions"}],"predecessor-version":[{"id":10722,"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/posts\/10548\/revisions\/10722"}],"wp:attachment":[{"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/media?parent=10548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/categories?post=10548"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sglux.de\/fr\/wp-json\/wp\/v2\/tags?post=10548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}