UV reference radiometers for UV purifier sensor validation
Reference radiometers for validation of water purifier duty sensors according to guideline DVGW W 294-3:2006 and ÖNORM M 5873 and DIN 19294
Showing all 4 results
-
UVRRM ÖNORM
Reference radiometer for validation of ÖNORM/DVGW-160° duty sensors, PTB traceable calibration according to ÖNORM M 5873 and DIN 19294Reference radiometer for validation of ÖNORM/DVGW-160° duty sensorsProduct Description- Reference radiometer for validation of ÖNORM/DVGW-160° duty sensors
- The unit is powered with a 9V battery that allows several years of use if seldomly used.
- PTB traceable calibration according to ÖNORM M 5873 and DIN 19294
-
UVRRM DVGW 40°
Reference radiometer for validation of 40° DVGW duty sensors, PTB traceable calibration according to DVGW W 294-3:2006Reference radiometer for validation of 40° DVGW duty sensorsProduct Description- Reference radiometer for validation of DVGW-40° duty sensors
- The unit is powered with a 9V battery that allows several years of use if seldomly used.
- PTB traceable calibration according to DVGW W 294-3:2006
-
UVRRM DVGW 40° + ÖNORM 160°
Reference radiometer with 2 UV sensors for validation of 40° DVGW and ÖNORM/DVGW-160° duty sensors, PTB traceable calibration according to DVGW W 294-3:2006 and ÖNORM M 5873 and DIN 19294Reference radiometer with 2 UV sensors for validation of 40° DVGW and ÖNORM/DVGW-160° duty sensorsProduct Description- Reference radiometer with two sensors for validation of 40°-DVGW and 160°-ÖNORM duty sensors.
- The unit is powered with a 9V battery that allows several years of use if seldomly used.
- PTB traceable calibration according to DVGW W 294-3:2006 and ÖNORM M 5873 and DIN 19294.
-
AQUATOUCH
2-channel reference radiometer for validation of 40° DVGW and/or ÖNORM/DVGW-160° duty sensors, PTB traceable calibration according to DVGW W 294-3:2006, ÖNORM M 5873 and DIN 19294. The AQUATOUCH device is designed for developers and for all-day use under harsh conditions. It offers a broad range of functions such as a datalogger, data export and graphic display with trend information.reference radiometer for validation of 40° DVGW and/or ÖNORM/DVGW-160° duty sensorsProduct Description- 2-channel reference radiometer for validation of DVGW-40° and/or ÖNORM/DVGW-160° duty sensors.
- PTB traceable calibration according to DVGW W 294-3:2006, ÖNORM M 5873 and DIN 19294.
- The AQUATOUCH device is designed for developers and for all-day use under harsh conditions.
- It offers a broad range of functions such as a datalogger, data export and graphic display with trend information.
- Delivered in a case including a DVGW or ÖNORM sensor.